Remedy
19
Electrical
Grounding
Check
all
components
for
electrical
short.
32
Outgoing
Water
Temperature
Sensor
Check
sensor
wiring
for
damage.
Measure
resistance
of
sensor.
Clean
sensor
of
scale
build
Ͳ
up.
Replace
sensor.
33
Heat
Exchanger
Outgoing
Temperature
Sensor
34
Combus
Ɵ
on
Air
Temperature
Sensor
Check
for
restric
Ɵ
ons
in
air
fl
ow
around
unit
and
vent
terminal.
Check
sensor
wiring
for
damage.
Measure
resistance
of
sensor.
Clean
sensor
of
scale
build
Ͳ
up.
Ensure
fan
blade
is
Ɵ
ght
on
motor
sha
Ō
and
is
in
good
condi
Ɵ
on.
Replace
sensor.
41
Outside
temperature
thermistor
(outdoor
models
only)
Check
sensor
wiring
for
damage.
Measure
resistance
of
sensor.
Clean
sensor
of
scale
build
Ͳ
up.
Replace
sensor.
51
Inlet
water
temperature
thermistor
(RL94
only)
52
Modula
Ɵ
ng
Solenoid
Valve
Signal
Check
modula
Ɵ
ng
gas
solenoid
valve
wiring
harness
for
loose
or
damaged
terminals.
Measure
resistance
of
valve
coil.
57
Burner
Contact
a
licensed
professional.
61
Combus
Ɵ
on
Fan
Ensure
fan
will
turn
freely.
Check
wiring
harness
to
motor
for
damaged
and/or
loose
connec
Ɵ
ons.
Measure
resistance
of
motor
winding.
65
Water
Flow
Control
The
water
fl
ow
control
valve
has
failed
to
close
during
the
bath
fi
ll
func
Ɵ
on.
Immediately
turn
o
ī
the
water
and
discon
Ɵ
nue
the
bath
fi
ll
func
Ɵ
on.
Contact
a
licensed
professional
to
service
the
appliance.
70
PC
Board
Check
PC
board
DIP
switches
for
correct
posi
Ɵ
on.
Check
the
connec
Ɵ
on
harness
at
the
connec
Ɵ
on
on
the
PC
board.
Replace
PC
board.
71
Solenoid
Valve
Circuit
Replace
the
PC
Board.
72
Flame
Sensing
Device
Verify
fl
ame
rod
is
touching
fl
ame
when
unit
fi
res.
Check
all
wiring
to
fl
ame
rod.
Remove
fl
ame
rod
and
check
for
carbon
build
Ͳ
up;
clean
with
sand
paper.
Check
inside
burner
chamber
for
any
foreign
material
blocking
fl
ame
at
fl
ame
rod.
Measure
micro
amp
output
of
sensor
circuit
with
fl
ame
present.
Replace
fl
ame
rod.
79
Water
Leak
Detected
Water
has
been
detected
at
the
bo
Ʃ
om
of
the
unit.
Turn
o
ī
water
supply.
Check
all
plumbing
internally
for
leakage.
LC
#
(LC0,
LC1,
LC2,…)
Scale
Build
Ͳ
up
in
Heat
Exchanger
(when
checking
maintenance
code
history,
“00”
is
subs
Ɵ
tuted
for
“LC”)
LC0~LC9
indicates
that
there
is
scale
build
up
in
the
heat
exchanger
and
that
the
heat
exchanger
needs
to
be
fl
ushed
to
prevent
damage.
Refer
to
the
fl
ushing
instruc
Ɵ
ons
in
the
manual.
Hard
water
must
be
treated
to
prevent
scale
build
up
or
damage
to
the
heat
exchanger.
To
operate
the
water
heater
temporarily
un
Ɵ
l
the
heat
exchanger
can
be
fl
ushed,
push
the
On/
O
ī
bu
Ʃ
on
on
the
temperature
controller
5
Ɵ
mes.
Repeated
LC
codes
will
eventually
lockout
the
water
heater.
Please
call
Rinnai
technical
department.
FF
Maintenance
has
been
performed
Indicates
a
licensed
professional
performed
maintenance
or
corrected
an
issue.
No
code
Nothing
happens
when
water
fl
ow
is
ac
Ɵ
vated.
Clean
inlet
water
supply
fi
lter.
On
new
installa
Ɵ
ons
ensure
hot
and
cold
water
lines
are
not
reversed.
Verify
you
have
at
least
the
minimum
fl
ow
rate
required
to
fi
re
unit.
licensed
professional
only
Check
for
cold
to
hot
cross
over.
Isolate
circula
Ɵ
ng
system
if
present.
Turn
o
ī
cold
water
to
the
unit,
open
pressure
relief
valve;
if
water
con
Ɵ
nues
to
fl
ow,
there
is
bleed
over
in
your
plumbing.
Verify
turbine
spins
freely.
Measure
the
resistance
of
the
water
fl
ow
control
sensor.
If
the
display
is
blank
and
clicking
is
coming
from
the
unit,
disconnect
the
water
fl
ow
servo
motor
(GY,
BR,
O,
W,
P,
BL,
R).
If
the
display
comes
on
then
replace
the
water
fl
ow
servo
motor.
licensed
professional
only