8
VC
Series
Manual
24"
V
Check
on
whether
local
codes
supersede
these
clearances.
x
Avoid
termina
Ɵ
on
loca
Ɵ
ons
near
a
dryer
vent.
x
Avoid
termina
Ɵ
on
loca
Ɵ
ons
near
commercial
cooking
exhaust.
x
You
must
install
a
vent
termina
Ɵ
on
at
least
12
inches
from
the
ground.
60"
V
V
(1.52
m)
between
terminals
at
di
ī
erent
levels
(0.61
m)
to
wall
or
parapet
(0.30
m)
between
terminals
at
same
level
12"
V
V
(1.52
m)
ver
Ɵ
cally
between
terminals
V
60"
V
Addi
Ɵ
onal
clearances
Ͳ
RL75i,
RL94i
12"
12"
36"
INSIDE
CORNER
V
V
(0.30
m
)
to
an
inside
corner
(0.30
m)
between
terminals
at
same
level
Important
considera
Ɵ
ons
for
loca
Ɵ
ng
vent
termina
Ɵ
on
under
a
so
ĸ
t
(ven
Ɵ
lated
or
unven
Ɵ
lated
or
eave
vent;
or
to
a
deck
or
porch)
x
Do
not
install
vent
termina
Ɵ
on
under
a
so
ĸ
t
vent
such
that
exhaust
can
enter
the
so
ĸ
t
vent
x
Install
vent
termina
Ɵ
on
such
that
exhaust
and
rising
moisture
will
not
collect
under
eaves.
Discolora
Ɵ
on
to
the
exterior
of
the
building
could
occur
if
installed
too
close.
x
Do
not
install
the
vent
termina
Ɵ
on
too
close
under
the
so
ĸ
t
where
it
could
present
recircula
Ɵ
on
of
exhaust
gases
back
into
the
combus
Ɵ
on
air
intake
part
of
the
termina
Ɵ
on.