20
VC
Series
Manual
Size
the
gas
pipe
The
gas
supply
must
be
capable
of
handling
the
en
Ɵ
re
gas
load
at
the
loca
Ɵ
on.
Gas
line
sizing
is
based
on
gas
type,
the
pressure
drop
in
the
system,
the
gas
pressure
supplied,
and
gas
line
type.
For
gas
pipe
siz
Ͳ
ing
in
the
United
States,
refer
to
the
Na
Ɵ
onal Fuel Gas
Code, NFPA 54
.
The
below
informa
Ɵ
on
is
provided
as
an
example.
The
appropriate
table
from
the
applica
Ͳ
ble
code
must
be
used.
1.
For
some
tables,
you
will
need
to
determine
the
cubic
feet
per
hour
of
gas
required
by
dividing
the
gas
input
by
the
hea
Ɵ
ng
value
of
the
gas
(available
from
the
local
gas
company).
The
gas
input
needs
to
include
all
gas
products
at
the
lo
Ͳ
ca
Ɵ
on
and
the
maximum
BTU
usage
at
full
load
when
all
gas
products
are
in
use.
2.
Use
the
table
for
your
gas
type
and
pipe
type
to
fi
nd
the
pipe
size
required.
The
pipe
size
must
be
able
to
provide
the
required
cubic
feet
per
hour
of
gas
or
the
required
BTU/hour.
Example:
The
hea
Ɵ
ng
value
of
natural
gas
for
your
loca
Ɵ
on
is
1000
BTU/FT
3
.
The
gas
input
of
the
RL94i
is
199,000
BTU/HR.
Addi
Ɵ
onal
appliances
at
the
loca
Ɵ
on
require
65,000
BTU/hr.
Therefore
the
cubic
feet
per
hour
=
(199,000
+
65,000)
/
1000
=
264
FT
3
/HR.
If
the
pipe
length
is
10
feet
then
the
3/4
inch
pipe
size
is
capable
of
supplying
264
FT
3
/HR
of
natural
gas.
Gas
Input
of
all
gas
products
(BTU
/
HR)
Hea
Ɵ
ng
Value
of
Gas
(BTU
/
FT
3
)
Cubic
Feet
per
Hour
=
(CFH)
x
Any
compound
used
on
the
threaded
joint
of
the
gas
piping
shall
be
a
type
which
resists
the
ac
Ɵ
on
of
lique
fi
ed
petroleum
gas
(propane
/
LPG).
x
The
gas
supply
line
shall
be
gas
Ɵ
ght,
sized,
and
so
installed
as
to
provide
a
supply
of
gas
su
ĸ
cient
to
meet
the
maximum
demand
of
the
heater
and
all
other
gas
consuming
appliances
at
the
loca
Ɵ
on
without
loss
of
pressure.
INFORMATION
x
Refer
to
an
approved
pipe
sizing
chart
if
in
doubt
about
the
size
of
the
gas
line.
Length
Pipe
Size
(inches)
3/4
1
1
1/4
1
1/2
10
273
514
1060
1580
20
188
353
726
1090
30
151
284
583
873
40
129
243
499
747
50
114
215
442
662
60
104
195
400
600
70
95
179
368
552
80
89
167
343
514
90
83
157
322
482
100
79
148
304
455
Pipe
Sizing
Table
Ͳ
Natural
Gas
Inlet
Pressure:
less
than
2
psi
(55
inches
W.C.)
Pressure
Drop:
0.3
inches
W.C.
Speci
fi
c
Gravity:
0.60
Schedule
40
Metallic
Pipe
cubic
feet
per
hour
Length
Pipe
Size
(inches)
1/2
3/4
1
1
1/4
10
291
608
1150
2350
20
200
418
787
1620
30
160
336
632
1300
40
137
287
541
1110
50
122
255
480
985
60
110
231
434
892
80
101
212
400
821
100
94
197
372
763
Pipe
Sizing
Table
Ͳ
Propane
Gas
Inlet
Pressure:
11.0
inches
W.C.
Pressure
Drop:
0.5
inches
W.C.
Speci
fi
c
Gravity:
1.50
Schedule
40
Metallic
Pipe
Capacity
in
Thousands
of
BTU
per
Hour
Содержание RL75e REU-VC2528WD(A)-US
Страница 28: ...28 VC Series Manual Ladder Diagram...
Страница 83: ...VC Series Manual 83...