Condensate
(indoor
models
only)
Condensate
forma
Ɵ
on
can
occur
in
high
e
ĸ
ciency
direct
vent
appliances.
Without
proper
drainage
condensate
will
damage
the
heat
exchanger.
To
prevent
condensate
damage
follow
these
instruc
Ɵ
ons.
DO
NOT
x
Do
not
allow
condensate
to
enter
the
water
heater.
x
Do
not
connect
the
condensate
drain
pipe
directly
to
the
rain
sewer.
x
Do
not
connect
the
condensate
drain
line
with
an
air
condi
Ɵ
oning
evaporator
coil
drain.
MUST
DO
x
Use
only
vent
that
is
approved
and
iden
Ɵ
fi
ed
as
acceptable
for
your
par
Ɵ
cular
model.
x
For
ver
Ɵ
cal
termina
Ɵ
ons,
install
a
condensate
drain
and
trap
as
close
as
possible
to
the
appliance.
x
Slope
the
ven
Ɵ
ng
toward
the
appliance
according
to
the
vent
manufacturers
installa
Ɵ
on
instruc
Ɵ
ons.
x
All
condensate
must
drain
and
be
disposed
of
according
to
local
codes.
x
Use
only
corrosion
resistant
materials
for
the
condensate
drain
lines
such
as
PVC
pipe
or
plas
Ɵ
c
hose.
x
The
condensate
drain
pipe
(along
its
en
Ɵ
re
length)
must
be
at
least
the
same
diameter
as
the
drain
line,
(5/8
inch
NPT).
x
The
end
of
the
condensate
drain
pipe
should
be
open
to
the
atmosphere.
The
end
should
not
be
under
water
or
other
substances.
x
To
minimize
freezing
of
the
condensate,
run
the
condensate
drain
line
through
an
interior
wall
or
between
insula
Ɵ
on
and
an
interior
wall.
x
The
condensate
collector
should
be
used
for
all
hydronic
hea
Ɵ
ng
applica
Ɵ
ons.
Checklist
for
Ven
Ɵ
ng
and
Condensate
(indoor
models
only)
ප
Verify
proper
clearances
around
the
vents
and
air
intakes.
ප
Ensure
you
have
used
the
correct
ven
Ɵ
ng
products
for
the
model
installed
and
that
you
have
completely
followed
the
ven
Ɵ
ng
manufacturer’s
installa
Ɵ
on
instruc
Ɵ
ons
and
these
installa
Ɵ
on
instruc
Ɵ
ons.
ප
Verify
that
the
vent
pipe
has
a
downward
slope
or
grade
to
the
outside
of
1/4
inch
per
foot
(1.2
°
)
OR
if
the
vent
pipe
is
sloped
toward
the
water
heater
(as
some
local
codes
require),
that
a
condensate
collector
is
installed
to
allow
condensa
Ɵ
on
to
drain
away
from
the
water
heater
to
a
proper
drain
source.
ප
Verify
that
condensate
will
not
be
allowed
to
drain
back
into
the
water
heater.
ප
Verify
that
the
vent
system
does
not
exceed
the
maximum
length
for
the
number
of
elbows
used.
INFORMATION
x
A
condensate
trap
is
available,
P/N
222053.
x
Regions
of
cold
climate
will
create
more
condensate
in
the
vent
system.
The
condensate
collector
should
be
used
in
cold
climates.
x
The
condensate
drain
pipe
should
be
as
short
as
possible
and
have
a
downward
pitch.