Linear installation guide 13563-H 08-19 |
35
This panel must be
non-combustible
up to timber lintel level
50 mm
50 mm
45°
3 mm
minimum air gap
Any materials within this area
must be rated as non-combustible
Walls must not protrude beyond
the front boundry line
non-combustible
lintel
No combustible materials
within 50mm of fire
Front edge of lips
400 mm
50 mm
50
3 mm
minimum air gap
45°
Any materials within this area
must be rated as non-combustible
Walls must not protrude beyond
the front boundry line
non-combustible
lintel if required
No combustible materials
within 50mm of fire
Front edge of lips
Opening size
C
minimum
Opening size
C
minimum
Outer Finishing Trim or
plaster finish appropriate
for high temp. applications
(up to 100 °C) or panel
edge finish, refer flush
panel finishing solutions.
400 mm
Front protruding
panels flush with lips
Non-combustible recess installations