Linear installation guide 13563-H 08-19 |
15
Linear 1000 minimum framing dimensions (mm)
Clearance (approx. 50 mm)
Shaded area denotes a clearance around the fire of approx. 50 mm.
On the RHS this is automatically achieved with the carry bar.
1450
796 min
500 **
~ 575
620
830
740
460
403
300
80**
870
945
403 mm assumes a 10 mm wallboard
on both sides of a double-sided unit.
415 mm is the min. for a single-sided
unit to maintain 50 mm clearance to
the back of the fire.
Glass centreline
Front face to
center of flue
Recommend that the lintel is left
until the fire is installed so min.
clearances can be maintained
39 assumes
10 mm wallboard
1565
945
1890 (for symmetrical cavity)
1016*
257
±5*
341*
•
All dimensions are assuming a 10 mm wallboard
•
Studs and joist are required directly below the support feet of the fire
•
Framing shown is 90 x 45 mm
•
Fire platform shown is 18 mm plywood
•
Allow room underneath the appliance for the gas supply to enter the fire cavity (min. 100 mm)
*
Minimum wallboard cutout, refer table on p.29
**
Maintain 25 mm clearance to combustibles for the first 500 mm of flue
The framing dimensions have the studs offset. This is because the cavity needs to be
framed based on the centreline of the Linear glass, NOT the opening size
.
Where there is a requirement for a symmetrical installation, the cavity size will need to
increase, refer diagram below.
IMPORTANT