Infinity REU-2007,2008,2408,2424
- 43 -
©Rinnai
3)
Is the modulating valve operating normal?
a. # Disconnect the modulating valve festoon
terminals and measure the resistance at the
terminals.
Normal:
60 ~ 100
If normal, go to (b.
Faulty:
Replace the modulating valve.
b. Re-connect terminal and measure the pink
~ pink voltage at the modulating valve
festoon terminal.
Normal:
DC 0.5 ~ 25 V
If normal, go to (c) below.
Faulty:
Replace PCB unit.
c. Investigate the change in gas secondary
pressure when the remote control preset
temperature is altered from 37 to 75 C.
Normal:
If the secondary pressure
changes, proceed to check item 4) below.
Faulty:
Replace the modulating valve.
4)
Is the water flow servo normal? (2008/2408)
a. # Disconnect connector and measure the
red ~ blue resistance on the water flow
servo side.
Normal:
10 ~ 30
S
If normal, go to b.
Faulty:
Replace the water flow servo with
water flow sensor.
b. Disconnect connector, and measure the
voltage between orange (+) and grey(-) on
the water flow control side.
Normal:
DC 11 ~ 13 V
If normal, go to (c).
Faulty:
Replace the PCB unit.
c. With connector (E
1
) connected (do not
turn water ON... wait for the water flow
servo to return to fully open), measure the
voltage between brown and grey.
Normal:
DC 4 ~ 6V
Faulty:
Change water flow servo with
sensor.
d. Leaving the relay connector (E
1
)
connected (do not turn water ON... wait for
the water flow servo to return to fully
open), measure the voltage between yellow
and grey.
Normal:
Less than DC 0.5 V
Faulty:
Change water flow servo with
sensor.
Ω
°
Содержание REU-2007W
Страница 1: ...INFINITY...
Страница 8: ...Infinity REU 2007 2008 2408 2424 3 Rinnai 1 2 Note All dimensions are in mm...
Страница 14: ...2 4 9 9...
Страница 15: ......
Страница 16: ...Infinity REU 2007 2008 2408 2424 11 Rinnai 2 4...
Страница 31: ...Infinity REU 2007 2008 2408 2424 26 Rinnai 3 A A 6 4 8...
Страница 32: ...Infinity REU 2007 2008 2408 2424 27 Rinnai 4 2 A Normal Combustion Sequence...
Страница 33: ...Infinity REU 2007 2008 2408 2424 28 Rinnai Error Sequence Ignition Flame Failure Pre Purge Defect Sequence...
Страница 62: ...Infinity REU 2007 2008 2408 2424 57 Rinnai 5 2 4...
Страница 63: ...Infinity REU 2007 2008 2408 2424 58 Rinnai...
Страница 64: ...Infinity REU 2007 2008 2408 2424 59 Rinnai...
Страница 65: ...Infinity REU 2007 2008 2408 2424 60 Rinnai...