Before starting inspection, re-check wiring harnesses and double check that all connections are tight.
Before carrying out checks marked with
*
, remove power cord from wall plug.
Nature of Fault
Examination
Point
Diagnostic Point
Values
Y/N
Action
Repair
N
o
A.
The ON
indicator does not
light up after
switching the unit
on.
1.
Is the power cord
plugged in?
Inspect visually
Is it plugged in?
Yes
Go to A-1.
No
Plug in cord
1
2.
Is supply voltage
correct?
Measure voltage at
power point.
AC 240 V
(NZ 230 V)
Yes
Go to A - 3.
No
Check power
supply circuit.
Check fuses.
2
3. Check 3 Amp
electrical fuses.
*Inspect visually
Is the surge
protector
indicator lit up
Yes
Go to A-5
No
Go to A-6
4.
Check 3 Amp
electrical fuses.
*
Disconnect and
measure resistance to
confirm if fuse is blown.
Normal< 1 M
Is fuse blown?
Yes
Go to A - 5 and
replace fuse.
No
Go to A - 6.
5.
Check for short
circuits.
i) Measure the resistance
of each solenoid valve.
*
Remove connector I
from the PCB before
measuring.
Pink - Black
0.9 ~ 1.3 k
Yellow - Black
1.3 ~ 1.9 k
Blue - Black
1.5 ~ 1.9 k
Are values within
those specified at
left?
N.B. Measure
after checking that
there are no
broken wires or
shorts.
Yes
Go to A-6-2)
No
Replace faulty
solenoid valves.
ii) Measure the sparker
resistance.
*
Disconnect the sparker
connector I
4
and
measure the resistance
between both terminals.
Is resistance >
1M
Yes
Go to A-5-iii)
No
Replace sparker
4
iii) Check wiring
Are there any
shorts?
Yes
Rectify/Replace
5
No
Replace PCB
6
6.
Check 240V-
100V transformer.
i) Measure voltage
between red-red A
1
connector.
AC 90~110 V
Yes
Go to A-6-ii)
No
Replace PCB.
ii) Measure voltage at
connectors A, F with
appliance on “standby”.
A, Green-Green
AC16 ~ 20 V
F, Orange-Orange
AC13 ~ 30 V
F, Brown-Grey
AC30 ~ 50 V
F, Yellow (LH)-Grey
AC180 ~ 220 V
Are values within
those specified at
left?
Yes
Go to A-7.
No
Replace 240V
transformer.
8
7.
Check the remote
control (where
connected).
Measure voltage
between the control
terminals at H
1
.
DC10 ~ 13 V.
Yes
Check cable for
shorts/broken
wires; replace
remote control.
9
No
Replace PCB.
10
Ω
Ω
Ω
Ω
Ω
Содержание REU-2007W
Страница 1: ...INFINITY...
Страница 8: ...Infinity REU 2007 2008 2408 2424 3 Rinnai 1 2 Note All dimensions are in mm...
Страница 14: ...2 4 9 9...
Страница 15: ......
Страница 16: ...Infinity REU 2007 2008 2408 2424 11 Rinnai 2 4...
Страница 31: ...Infinity REU 2007 2008 2408 2424 26 Rinnai 3 A A 6 4 8...
Страница 32: ...Infinity REU 2007 2008 2408 2424 27 Rinnai 4 2 A Normal Combustion Sequence...
Страница 33: ...Infinity REU 2007 2008 2408 2424 28 Rinnai Error Sequence Ignition Flame Failure Pre Purge Defect Sequence...
Страница 62: ...Infinity REU 2007 2008 2408 2424 57 Rinnai 5 2 4...
Страница 63: ...Infinity REU 2007 2008 2408 2424 58 Rinnai...
Страница 64: ...Infinity REU 2007 2008 2408 2424 59 Rinnai...
Страница 65: ...Infinity REU 2007 2008 2408 2424 60 Rinnai...