Infinity REU-2007,2008,2408,2424
- 37 -
©Rinnai
Refer to diagram on
bottom of previous page.
c. Check the voltage at centre PCB connector
F, green~green.
Normal:
AC 16 ~ 20V
If normal, check item 3) below.
Faulty:
Replace the transformer.
Note:
Transformer voltage above applies
to the appliance in a standby, non-
functioning state.
3)
Is the remote control normal?
Check voltage between the two remote
control cable conductors.
a. Check the voltage between terminals on
the remote control terminal mount (H
1
).
Normal:
DC 10 ~ 13V
If normal, check for open circuit or
shorts before replacing the remote
control.
Faulty:
Replace PCB.
No combustion (despite remote control indication)
a. Measure the voltage between red and
black of the relay connector (a
2
).
Normal:
DC 11 ~ 13V
If normal, go to (b).
Faulty:
Replace water flow control.
b. Measure the voltage between yellow and
black of the relay connector (a
2
)
Normal:
DC 2 ~ 10V
If normal, go to 2).
Faulty:
Replace the water flow sensor.
Содержание REU-2007W
Страница 1: ...INFINITY...
Страница 8: ...Infinity REU 2007 2008 2408 2424 3 Rinnai 1 2 Note All dimensions are in mm...
Страница 14: ...2 4 9 9...
Страница 15: ......
Страница 16: ...Infinity REU 2007 2008 2408 2424 11 Rinnai 2 4...
Страница 31: ...Infinity REU 2007 2008 2408 2424 26 Rinnai 3 A A 6 4 8...
Страница 32: ...Infinity REU 2007 2008 2408 2424 27 Rinnai 4 2 A Normal Combustion Sequence...
Страница 33: ...Infinity REU 2007 2008 2408 2424 28 Rinnai Error Sequence Ignition Flame Failure Pre Purge Defect Sequence...
Страница 62: ...Infinity REU 2007 2008 2408 2424 57 Rinnai 5 2 4...
Страница 63: ...Infinity REU 2007 2008 2408 2424 58 Rinnai...
Страница 64: ...Infinity REU 2007 2008 2408 2424 59 Rinnai...
Страница 65: ...Infinity REU 2007 2008 2408 2424 60 Rinnai...