Riland CUT 100GT Скачать руководство пользователя страница 6

 

 

The gas and fumes are harmful to health, please wear protective device 

according to regulations. 

 

˜

  Wear exhaust equipment and breathe preventive facilities to prevent gas poisoning or choke.

 

˜

  Use suggested part exhaust equipment and breathe preventive facilities to prevent hurt or 

poisoning by gas and other powder, please.

 

˜

  To prevent oxygen-deficiency, air out the gas-filled room which is full of CO

and argon on the 

bottom, when operating on trunks, boilers, cabins, etc.

 

˜

  Please accept 

the supervisor’s inspection when operating in narrow space. Air the room and 

wear breathe preventive facilities.

 

˜

  Never operate in degrease, washing or spray space.

 

˜

  Using breathe preventive facilities when cut shielded steel for it will cause poisonous dust and 

gas.

 

 

  

The arc, spark, residue and noise are harmful to health, please wear 

protective appliance. 

 

˜

  Eye protection against arc is recommended when cutting or supervise cutting.

 

˜

  Please wear preventive spectacles.

 

˜

 

Operator’s gloves, operator’s goggles, long sleeve clothes, leather apron, and other standard 
protection equipments must be worn for cutting operation.

 

˜

  A screen to protect other people against the arc must be set in the cutting place.

 

 
 
 

Please follow the notes below to avoid gas cylinder toppling over or 

broken. 

 

˜

  Use the gas cylinder correctly.

 

˜

  Use the equipped or recommended gaseous regulator.

 

˜

  Read the manual of gaseous regulator carefully before using it, and pay attention to the safety 

notes.

 

˜

  Fix the gas cylinder with appropriative holder and other relative parts.

 

˜

  Never put the cylinder under high temperature or sunshine environment.

 

˜

  Keep your face away from the gas cylinder exit when opening it.

 

˜

  Put on the gas shield when it is not used.

 

˜

  Never put the torch on the gas cylinder. The electrode cannot meet the gas cylinder.

 

 
 
 

Any touch of the switch part will cause injury, please note the 

following. 

 

˜

  Never use the machine when the enclosure is off.

 

˜

  Install, operate, check and maintain the machine by professional person.

 

˜

  Keep your fingers, hair, clothes etc. away from the switch parts such as the fan.

 

Содержание CUT 100GT

Страница 1: ...CUT 100GT PLASMA CUTTING MACHINE USER MANUAL...

Страница 2: ...t or property lose if it is not followed The words after this sign means there is potential risk which may cause equipment fault or break if it is not followed Version Version YF TAE 0071 A3 Released...

Страница 3: ...11 AIR REGULATOR INSTALLATION AND OPERATION 12 PANEL FUNCTION INSTRUCTION 13 PANEL FUNCTION INSTRUCTION 14 START AIR PLASMA CUTTING 15 NOTES OR PREVENTIVE MEASURES 16 QUESTIONS TO BE RUN INTO DURING C...

Страница 4: ...may cause choke Spark and hot workpiece after cutting may cause fire Bad connected cable may cause fire Incompletion connection of workpiece side circuit may cause fire Never cut on the case of tinde...

Страница 5: ...art 5 minutes later The capacitance is chargeable device Please ensure it has no voltage before start again even if the power source is cut off Do not use wire with inadequate section surface or damag...

Страница 6: ...ear preventive spectacles Operator s gloves operator s goggles long sleeve clothes leather apron and other standard protection equipments must be worn for cutting operation A screen to protect other p...

Страница 7: ...5 to the vertical direction When lifting the plasma cutting machine which equipped with gas cylinder and wire feeder download them from the power source and ensure the horizontal of the machine Do fix...

Страница 8: ...f the cutting and other activities Users should observe the following dos and don ts to decrease radiation interference a Connect the cutting equipments to the power supply lines b Maintain the cuttin...

Страница 9: ...asma arc It has the functions of arc initiation current arc stop current cutting current basic value current current ascending time current descending time post gas time continuous adjustment What s m...

Страница 10: ...o load voltage V 300 328 Current Range A 20 100 Rate output voltage V 120 Duty cycle 40 Efficiency 85 Power factor 0 9 Post flow time S 5 20 Insulation Class H Housing Protection Class IP21 Arcing Way...

Страница 11: ...ource does not meet the above requirements you should consider using sole compressor of the right power and air decompressing filter in order to supply suitable pressure and eliminate the impurity and...

Страница 12: ...air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows Kgf cm2 and then put down the knob means increasing pressure means decreasing pressure 6 Scale of the...

Страница 13: ...icator 11 Plasma cutting torch switch socket 4 Over current protect indicator 12 Negative output terminal 5 Current digital meter 13 Power switch 6 Pressure meter 14 Air in 7 Post gas adjusting knob 1...

Страница 14: ...ol machine 3 Over heat low gas pressure lose phase protect indicator Over heat When the temperature of power parts exceeds its limit the indicator lighting for protection and the machine stops After c...

Страница 15: ...essure and flow Press cut air test button again return to cut 3 Choose 2T 4T function according to the cutting requirement 4 Adjusting the current and post gas knob according to the thickness and tech...

Страница 16: ...lated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to watch the max duty current Response to the selected duty cycle Keep cuttin...

Страница 17: ...and input cable is too long C Output current is not up to the rated value When power voltage departs from the rated value it will make the output current not matched with rated value when voltage is l...

Страница 18: ...er machine if they enter into machine please dry inter machine then check insulation of machine 5 If plasma cutting machine will not be operated long time it must be put into packing box and store in...

Страница 19: ...4 Control board is broken 5 Feeding circuit broken abnormal indicator lit contact factory Meter is normal fan is normally working electromagnetic valve is abnormal no arc output abnormal indicator is...

Страница 20: ...CIRCUIT DIAGRAM...

Отзывы: