14
PANEL FUNCTION INSTRUCTION
1
、
Cut/gas switch
:
Cut normal cutting.
:
Gas test used for power gun cable and gas pressure adjustment. When adjusting the gas
pressure, the indicator lighting, then adjust the air reducing valve of the rear panel, the gas pressure
meter of front panel w indicates the pressure.
2
、
2T/4T switch
2T
:
Press the button for cutting, release for stop.
4T
:
Press the button: start cutting, release and press again: continue cutting, release again, stop
cutting. Suitable for digital control machine.
3
、
Over-heat/low gas pressure/lose phase protect indicator
Over-heat
:
When the temperature of power parts exceeds its limit,the indicator lighting for protection;
and the machine stops. After cooling, return to normal.
Low gas pressure
:
When the indicated pressure below 2.5 kgf/cm2, the indicator lighting, machine
stop. After the pressure became normal, machine return to normal.
Lose phase protection
:
When the input power lose phase the indicator lighting for protection, machine
stops. And return to normal after the power became normal.
4
、
Pressure meter
Indicate the pressed air pressure, indicating range: 0-10kgf/cm2.
5
、
Post gas adjusting knob
Adjust the post gas time, adjusting range
:
5~20s