Riland CUT 100GT Скачать руководство пользователя страница 16

16 

 

 

NOTES OR PREVENTIVE MEASURES 

 

 

 

1

  The machine can perform in environment where conditions are dry with a dampness level of 

max 90%. 

2

  Ambient temperature is between -10 to 40 degrees centigrade. 

3

  Avoid cutting in sunshine or drippings. Do not let water enter the gas. 

4

 

Avoid cutting in dust area or the environment with corrosive gas. 

5

 

Avoid gas cutting in the environment with strong airflow. 

 

Our plasma cutting machine has installed protection circuit of over voltage, over current and over 

heat. When voltage, output current and temperature of machine are exceeding the rate standard, 

plasma  cutting  machine  will  stop  working  automatically.  Because  that  will  be  damage  to  plasma 

cutting machine, user must pay attention to following. 

 

1

 

The working area is adequately ventilated

 

 

Our plasma cutting machine is powerful machine, when it is being operated, it generated by high 

currents, and natural wind c

an’t be satisfied with machine cool demands. So, there is a fan in 

inter-machine to cool down machine. Make sure the intake is not in block or covered, it is 0.3 

meter  from  plasma  cutting  machine  to  objects  of  environment.  User  should  make  sure  the 

working area is adequately ventilated. It is important for the performance and the longevity of 

the machine. 

2

 

Do not over load

 

 

The operator should remember to watch the max duty current (Response to the selected duty 

cycle). Keep cutting current is not exceed max duty cycle current. Over-load current will damage 

and burn up machine. 

3

 

No over voltage

 

 

Power voltage can be found in diagram of main technical data. Automatic compensation circuit 

of voltage will assure that cutting current keeps in allowable range. If power voltage is exceeding 

allowable  range  limited,  it  is  damaged  to  components  of  machine.  The  operator  should 

understand this situation and take preventive measures. 

 

4

 

There  is  a  grounding  screw  behind  plasma  cutting  machine,  with  a  grounding  marker  on  it. 

Before  operation,  cutting  crust  must  be  grounded  reliable  with  cable  which  section  is  over  6 

square millimeters, in order to prevent from static electricity, and accidents because of electricity 

leaking. 

5

 

If  cutting  time  is  exceeded  duty  cycle  limited,  plasma  cutting  machine  will  stop  working  for 
protection. Because machine is overheated, temperature control switch is on “ON’’ position and 
the indicator light is red. In t

his situation, you don’t have to pull the plug, in order to let the fan 

cool the machine. When the indicator light is off, and the temperature goes down to the standard 

range, it can cut again. 

1. 

Environment 

2. Safety norms 

Содержание CUT 100GT

Страница 1: ...CUT 100GT PLASMA CUTTING MACHINE USER MANUAL...

Страница 2: ...t or property lose if it is not followed The words after this sign means there is potential risk which may cause equipment fault or break if it is not followed Version Version YF TAE 0071 A3 Released...

Страница 3: ...11 AIR REGULATOR INSTALLATION AND OPERATION 12 PANEL FUNCTION INSTRUCTION 13 PANEL FUNCTION INSTRUCTION 14 START AIR PLASMA CUTTING 15 NOTES OR PREVENTIVE MEASURES 16 QUESTIONS TO BE RUN INTO DURING C...

Страница 4: ...may cause choke Spark and hot workpiece after cutting may cause fire Bad connected cable may cause fire Incompletion connection of workpiece side circuit may cause fire Never cut on the case of tinde...

Страница 5: ...art 5 minutes later The capacitance is chargeable device Please ensure it has no voltage before start again even if the power source is cut off Do not use wire with inadequate section surface or damag...

Страница 6: ...ear preventive spectacles Operator s gloves operator s goggles long sleeve clothes leather apron and other standard protection equipments must be worn for cutting operation A screen to protect other p...

Страница 7: ...5 to the vertical direction When lifting the plasma cutting machine which equipped with gas cylinder and wire feeder download them from the power source and ensure the horizontal of the machine Do fix...

Страница 8: ...f the cutting and other activities Users should observe the following dos and don ts to decrease radiation interference a Connect the cutting equipments to the power supply lines b Maintain the cuttin...

Страница 9: ...asma arc It has the functions of arc initiation current arc stop current cutting current basic value current current ascending time current descending time post gas time continuous adjustment What s m...

Страница 10: ...o load voltage V 300 328 Current Range A 20 100 Rate output voltage V 120 Duty cycle 40 Efficiency 85 Power factor 0 9 Post flow time S 5 20 Insulation Class H Housing Protection Class IP21 Arcing Way...

Страница 11: ...ource does not meet the above requirements you should consider using sole compressor of the right power and air decompressing filter in order to supply suitable pressure and eliminate the impurity and...

Страница 12: ...air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows Kgf cm2 and then put down the knob means increasing pressure means decreasing pressure 6 Scale of the...

Страница 13: ...icator 11 Plasma cutting torch switch socket 4 Over current protect indicator 12 Negative output terminal 5 Current digital meter 13 Power switch 6 Pressure meter 14 Air in 7 Post gas adjusting knob 1...

Страница 14: ...ol machine 3 Over heat low gas pressure lose phase protect indicator Over heat When the temperature of power parts exceeds its limit the indicator lighting for protection and the machine stops After c...

Страница 15: ...essure and flow Press cut air test button again return to cut 3 Choose 2T 4T function according to the cutting requirement 4 Adjusting the current and post gas knob according to the thickness and tech...

Страница 16: ...lated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to watch the max duty current Response to the selected duty cycle Keep cuttin...

Страница 17: ...and input cable is too long C Output current is not up to the rated value When power voltage departs from the rated value it will make the output current not matched with rated value when voltage is l...

Страница 18: ...er machine if they enter into machine please dry inter machine then check insulation of machine 5 If plasma cutting machine will not be operated long time it must be put into packing box and store in...

Страница 19: ...4 Control board is broken 5 Feeding circuit broken abnormal indicator lit contact factory Meter is normal fan is normally working electromagnetic valve is abnormal no arc output abnormal indicator is...

Страница 20: ...CIRCUIT DIAGRAM...

Отзывы: