Combined operation
Automatic ignition of firewood during start-up, or automatic log
recognition during operation�
Automatic ignition of firewood during start-up
Place two logs into the firebox� Be sure that at least one of the logs
lays above the combustion trough to facilitate burning� Close firebox
door�
Start stove operation� After ignition has been successful, the
operating state
IGNITION
switches to
LOG CHECK
, and after
successful log recognition to
LOG OPERATION
�
Note
If no more logs are reloaded, pellet operation starts automatically
again as the unit is still on�
Automatic log detection during operation
Open the firebox door and place 2 logs into the box� Be sure that
at least one of the logs lays above the ignition trough to facilitate
burning�
Close firebox door� The operating state switches from
CONTROLLED OPERATION
to
LOG CHECK
, and after successful log
recognition to
LOG OPERATION
�
Note
If no more logs are reloaded, pellet operation restarts automatically
as the unit is still on�
If you switch the combi stove off during log operation, the operating
state will change to
STOVE OFF
after the logs have burned down�
Easy-refilling operation
In order to reduce the discharge of fluegas when refilling logs there
is a easy-refilling operation available�
unhide additional
functions
hide additional
functions
Open the fluegas
flap
Wait about 3 seconds before you open the combustion chamber
door to refuel�
After closing the combustion chamber door, turn the wrench
clockwise to close the fluegasflap�
Tip
If the flue gas flap is open, a warning appears on the display� It
expires when you close the flue gas flap�
Note
Pellet operation is not possible with an opened flue gas flap�
Log operation in case of power breakdown
Note
Your stove must be disconnected from the mains for current-free
operation�
Note
Any modification of the procedure stated above may result in
damaging of components, which automatically will void any
warranty claims�
Insert the socket spanner supplied in the sleeve, as shown�
Turn it clockwise until a slight stop can be felt�
Remove the socket spanner from the opening and insert it again in
horizontal position�
Turn the spanner ant-clockwise until it is flush with the marking in
the side panel (approx� 45°)� It is now in heating up position�
After heating-up has been successful, turn the spanner anti-
clockwise step by step to reduce the combustion air manually, thus
regulating the burn-off�
Each time logs are added, the spanner must be brought into heating
up positon again� The combustion air is regulated as described
above�
Note
Always ensure that the stove has enough air for combustion� Clean
the fire trough manually�