background image

|9

EN

8

Note: Please consider the powdercoated parts can differ slightly in colour and colour effects though they are elaborated in high quality�

Nr. Art.Nr.

Description

132

L02726

Small plate

133

N112391

Wing screw

134

Z36000

Cleaning cover

135

Z36566

Sealing

136

Z35999

Cleaning cover

137

Z36567

Sealing

138

L02658

Ash drawer

139

N112197

Hexagon socket screw

140

Z38486

Fire trough

141

N111631

Round sealing cord grey D06

150

LB00802

Convection cover

151

Z36001

Snap spring

152

L03879

Rear wall top

153

L03667

Cover plate sensor

154

N112185

Self-tapping screw

155

N112240

Self-tapping screw

156

LB00898

Side panels top right

157

N108121

Self-tapping screw

158

N112432

Hexagonal nut

159

Z38088

Stop bolt for magnet

160

L03663

Side casing panel, right

161

N111730

Grommet

162

Z37809

Support pad, silicone

163

Z37463

Front soap stone

164

B17390

Stone retainer assy

165

L02239

Cover plate

166

N111970

Hexagonal nut M08

167

N112490

Levelling screw black

168

L03664

Side casing panel, left

169

N112419

Wing screw

170

L03878

Rear wall left

171

L02653

Rear wall cover black

172

L03665

Rear wall right

173

N112018

Key

174

Z35691

Spring plug

175

Z38576

Protective plate

176

N112240

Self-tapping screw

177

LB00801

Container lid

178

N112600

Container seal

179

L02349

Lock washer

180

N110461

Double ball catch

181

N112144

Washer

182

N112143

Hexagonal nut M03

183

N112446

Hexagonal countersunk screw

185

L01445

Switch spacer

186

N111732

Magnetic switch top part

187

N111842

Hexagon socket M03x10

188

N111733

Magnetic switch bottom part

189

L02243

Hinge lid

190

N110501

Circlips

191

Z34854

Hinge shaft

192

N112142

Flange nut

193

N111956

Grub screw

194

L02244

Hinge stove

200

B17289

Touch-display

201

N112769

Halogen lamp

202

N112759

Cross-head screw

Nr. Art.Nr.

Description

203

B18907

Oven lighting complete

204

Z38547

Sealing internal

205

L03868

Holder for lighting

206

N111975

Hexagonal nut

207

Z38548

Sealing central

208

Z38550

Sealing external

209

Z38549

Cover

210

N108121

Self-tapping screw

211

B18619

Sensor tube

212

Z38094

Washer

213

L03830

Washer hot zinc dipped

214

N112768 

Temperature sensor

215

N111793

Self-tapping screw

216

N112487

Washer

217

Z36290

Seal for ignition

218

B17166

Ceramic ignition

219

Z35183

Friction bearing Di10

220

B12301

Auger

221

Z35182

Friction bearing Di16

222

Z11915

Lock ring conveyer screw

223

N111058

Setscrew with pin

224

N112030

Screw motor, stepless

225

N111825

Contact switch

226

N112274

Hexagonal nut

227

N100170

Washer

228

L02646

Actuating cam dumping grate 

229

L02644

Retaining plate

230

N112014

Turning grid motor assy

231

N112146

Hexagon socket screw

232

N111843

Washer M08

233

L02643

Motor plate

234

Z18105

Hose

235

L03484

Heat protection

236

N111806

Hexagonal screw

237

N101570

Hexagonal screw

238

B16951

Induced draft fan housing

239

N112305

Self-tapping screw

240

N111581

Induced draft fan motor

241

N106989

Hexagonal screw

242

N111551

Silicon hose

243

N112316

T-Joint

244

Z35943

Cable channel

245

N112240

Self-tapping screw

246

N100169

Washer

247

N111989

USB cable

248

N112703

Self-tapping screw

249

Z38387

IEC mains socket

250

B16561

Mainboard USB11

252

B18868

Aditional motherboard for lighting

253

B16030

Additional motherboard for motor, incl. cable

254

L03638

Holder plate

255

N112473

Differential pressure sensor

256

N112102

Differential pressure switch

257

Z36760

Pressure Pipe

258

N109185

Circlips D04

259

B16053

Sensor tube

260

B16114

Temperature sensor

Spare part overview article numbers

Содержание DOMO Back

Страница 1: ...DOMO BACK Operating manual...

Страница 2: ...ction 13 4 BRIEF INFORMATION ON FUEL PELLETS 14 What are pellets 14 Wood pellet specification according to ENplus A1 14 Pellet container refilling during operation 14 Pellet storage 14 5 TECHNOLOGY AN...

Страница 3: ...aces 22 9 CLEANING 23 Clean convection air openings 23 Clean combustion air intake 23 Clean pellet container 23 Clean flue gas channels and flue gas collecting duct 23 Clean flue pipes 24 Check bearin...

Страница 4: ...33 35 40 41 42 51 10 19 10 13 6 20 6 18 10 10 12 19 20 6 13 6 9 8 11 10 14 17 15 16 7 6 5 2 3 4 21 22 24 24 25 25 23 23 23 26 26 53 52 16 54 31 45 43 27 27 40 41 42 44 38 38 39 39 4 4 29 29 29 29 32 3...

Страница 5: ...3 85 87 81 80 85 82 82 82 91 92 90 89 88 138 137 136 82 135 134 133 140 131 132 132 96 96 141 139 115 130 128 129 127 126 125 123 124 119 122 120 121 118 117 116 115 115 114 113 85 114 113 85 114 113...

Страница 6: ...158 159 155 155 157 152 154 153 168 161 169 160 161 155 170 161 171 154 153 154 154 172 161 154 173 174 154 167 194 194 189 189 191 191 190 190 193 193 177 183 187 176 176 176 185 188 178 175 180 192...

Страница 7: ...4 201 206 207 209 208 210 224 238 240 241 215 239 247 259 249 250 243 242 242 248 253 252 245 246 256 244 246 246 254 210 255 244 233 230 235 236 237 229 227 226 228 227 226 225 234 232 231 257 258 22...

Страница 8: ...804 Decorative door 56 N112382 Hexagonal countersunk screw 57 L02714 Magnet washer 58 N112111 Rubber buffer Nr Art Nr Description 59 N112175 Washer 60 N112729 Spacer 61 N109233 Hexagonal nut 70 Z32838...

Страница 9: ...956 Grub screw 194 L02244 Hinge stove 200 B17289 Touch display 201 N112769 Halogen lamp 202 N112759 Cross head screw Nr Art Nr Description 203 B18907 Oven lighting complete 204 Z38547 Sealing internal...

Страница 10: ...10 Exhaust g s 6 2 Exhaust temperature C 178 1 Chimney draft requirement Pa 3 The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentat...

Страница 11: ...e connection must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular...

Страница 12: ...at resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q W...

Страница 13: ...wind break 2 chimney 3 inspection opening For the selection of the connection and to ensure a proper connection between the stove and chimney please read the guide INSTALLING THE STOVE or ask your loc...

Страница 14: ...h a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manufa...

Страница 15: ...ng the operational safety The status indicator CLEAN appears on the display Only for stoves with turning grids Every 6 hours interval adjustable an additionally automatic big cleaning cycle is perform...

Страница 16: ...ur fingers and any panels and stove attachments Select soft bases to prevent scratches to your living space furniture and stove panels Tip Right Left according to standing in front of the stove Disman...

Страница 17: ...o wing screws off the side panel Tilt the panel outwards and lift it up Open the pellet container lid until it stops In this position it remains open Remove the two hexagonal screws Tilt the side pane...

Страница 18: ...container they can block the screw conveyor and damage the stove Note During any conversion work take particular care of your fingers and any panels and stove attachments Select soft bases to prevent...

Страница 19: ...ainst each other Place the correspondent flue pipe on the side Make sure that everything is tight Install the removed parts in reverse order Rear top connection R4 Remove the handle of the flue gas fl...

Страница 20: ...ting shield Note Operation of the stove without an assembled heat protectingshield is not allowed and leads to loss of warranty Place the 90 elbow with cleaning lid to the flue gas stack Make sure tha...

Страница 21: ...rated in either MANUAL or AUTOMATIC MODE In both MODES the current set heat output is used in AUTOMATIC MODE the heating times set at the stove can also be activated You can see whether the external d...

Страница 22: ...or clinker from the combustion chamber from the fire trough and the turning grid regularly Use the cleaning function to put the grid vertical Remove the clinker using the brush supplied and sweep the...

Страница 23: ...lean combustion air intake Note Only when the stove is cold You could vacuum out embers FIRE RISK If necessary please also clean the air intake with a hoover Clean pellet container Do not refill the c...

Страница 24: ...t and dust deposits in the fire and in the flue pipes and vacuum Note Accumulated fly ash in the flue gas channels may impair the performance of the stove and pose a safety risk Check bearings annuall...

Страница 25: ...see CLEANING and MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end...

Страница 26: ...se are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in...

Страница 27: ...ght Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YES...

Страница 28: ...fessional certified for that type of stove The installation is performed by a RIKA certified technician The stove is registered with RIKA by the RIKA specialist dealer importer on the RIKA Service Por...

Страница 29: ...uct life cycle In accordance with the European Directive 2012 19 EU Waste Electrical and Electronic Equipment WEEE and other local regulations RIKA supports the setup of take back systems and recyclin...

Страница 30: ......

Страница 31: ...31 EN 30...

Страница 32: ...ly valid one Subject to technical and visual changes as well as layout and printing errors 2020 RIKA Innovative Ofentechnik GmbH Z38569_Domo_Back_EN 16 07 2020 RIKA Innovative Ofentechnik GmbH M llerv...

Отзывы: