background image

|27

EN

26

Pictures made of ACTUAL condition

Guarantee conditions described

Relay testing (component testing)

Chimney type

Differential pressure sensor (building)

Smooth operation of backfire safety flap checked (combi stove)

Function checked

GSM modem

Surname, forename

User signature

Place, date

Signature & stamp of commissioning technician

Street, number

Post-code, city

E-mail, phone

Retailer stamp

Device type

Serial number

Cladding undamaged?

 YES

 NO

Phone provider

Software version

Display version

Connection socket grounded

Model

Room thermostat

Smooth operation of flues gas flap checked (combi stove)

Fire alarm in place?

 YES

 NO

Fire-proof floor covering in place?

 YES

 NO

Other

BRICKS

 STAINLESS STEEL

FIRECLAY

Chimney diameter

Chimney height

Chimney – approved by inspection authority?

 YES

 NO

Chimney system

Number of deflector plates

Length of smoke pipes

Smoke pipes in connection system

 WITH

 WITHOUT

SEALING LIP

Door/bricks/cladding checked and adjusted(function/gaps)

Pellet quality explained (env. standard/DIN plus/ENplus-A1)

Device function/control explained

Maintenance contract

Soot brush

Thermal gloves

Door opener

 Care and maintenance log

 available and handed over to the user

User manual explained and handed over

Year of production

Model

FIRENET

 YES

 NO

Proper installation according to installation and user manuals

Room height

Room ventilation

Exhaust hood (outdoor connection)

WC extraction

Comments

Central vacuum cleaning system

 YES

 NO

 YES

 NO

 YES

 NO

 YES

 NO

Chimney draft (full load)

Outside temperature

Plaster openings

 YES

 NO

Cleaning & maintenance interval, maintenance checklist explained

Warranty conditions explained

Stove taken into operation with the client

Stove switched off and handed over

Independently of room air

 YES

 NO

 YES

 NO

 Above sea level

 INDOOR

 OUTDOOR

 YES

 NO

www.rika.eu

 Dated: 08/07/2020

COMMISSIONING REPORT

for RIKA pellet and combi stoves. 

Dated 07/2020

ORIGINAL - REMAINS WITH CLIENT

Installation address

RIKA retailer

Device data

Electrical peripherals

Inspection of system and safety components

Flue gas line/chimney

Device functions

Initial user instruction

Installation

RIKA Innovative Ofentechnik, 4563 Micheldorf, Müllerviertel 20, Austria, hereby confirms that the provided personal data is exclusively used for in-house purposes, processing  
and recording. The client confirms the reception of correct and clear instructions. Our general terms and conditions shall apply.

I consent to the collection, saving and use of my personal data (name, address, e-mail) by RIKA Innovative Ofentechnik GmbH for marketing and information purposes.  
This consent can be withdrawn at any time and without any charge and formless under [email protected]

ATTENTION:  

Compliance with national regulations and laws as well as locally applicable rules and regula-

tions is within the responsibility of the specialist contractor commissioned with installation.

Содержание DOMO Back

Страница 1: ...DOMO BACK Operating manual...

Страница 2: ...ction 13 4 BRIEF INFORMATION ON FUEL PELLETS 14 What are pellets 14 Wood pellet specification according to ENplus A1 14 Pellet container refilling during operation 14 Pellet storage 14 5 TECHNOLOGY AN...

Страница 3: ...aces 22 9 CLEANING 23 Clean convection air openings 23 Clean combustion air intake 23 Clean pellet container 23 Clean flue gas channels and flue gas collecting duct 23 Clean flue pipes 24 Check bearin...

Страница 4: ...33 35 40 41 42 51 10 19 10 13 6 20 6 18 10 10 12 19 20 6 13 6 9 8 11 10 14 17 15 16 7 6 5 2 3 4 21 22 24 24 25 25 23 23 23 26 26 53 52 16 54 31 45 43 27 27 40 41 42 44 38 38 39 39 4 4 29 29 29 29 32 3...

Страница 5: ...3 85 87 81 80 85 82 82 82 91 92 90 89 88 138 137 136 82 135 134 133 140 131 132 132 96 96 141 139 115 130 128 129 127 126 125 123 124 119 122 120 121 118 117 116 115 115 114 113 85 114 113 85 114 113...

Страница 6: ...158 159 155 155 157 152 154 153 168 161 169 160 161 155 170 161 171 154 153 154 154 172 161 154 173 174 154 167 194 194 189 189 191 191 190 190 193 193 177 183 187 176 176 176 185 188 178 175 180 192...

Страница 7: ...4 201 206 207 209 208 210 224 238 240 241 215 239 247 259 249 250 243 242 242 248 253 252 245 246 256 244 246 246 254 210 255 244 233 230 235 236 237 229 227 226 228 227 226 225 234 232 231 257 258 22...

Страница 8: ...804 Decorative door 56 N112382 Hexagonal countersunk screw 57 L02714 Magnet washer 58 N112111 Rubber buffer Nr Art Nr Description 59 N112175 Washer 60 N112729 Spacer 61 N109233 Hexagonal nut 70 Z32838...

Страница 9: ...956 Grub screw 194 L02244 Hinge stove 200 B17289 Touch display 201 N112769 Halogen lamp 202 N112759 Cross head screw Nr Art Nr Description 203 B18907 Oven lighting complete 204 Z38547 Sealing internal...

Страница 10: ...10 Exhaust g s 6 2 Exhaust temperature C 178 1 Chimney draft requirement Pa 3 The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentat...

Страница 11: ...e connection must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular...

Страница 12: ...at resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q W...

Страница 13: ...wind break 2 chimney 3 inspection opening For the selection of the connection and to ensure a proper connection between the stove and chimney please read the guide INSTALLING THE STOVE or ask your loc...

Страница 14: ...h a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manufa...

Страница 15: ...ng the operational safety The status indicator CLEAN appears on the display Only for stoves with turning grids Every 6 hours interval adjustable an additionally automatic big cleaning cycle is perform...

Страница 16: ...ur fingers and any panels and stove attachments Select soft bases to prevent scratches to your living space furniture and stove panels Tip Right Left according to standing in front of the stove Disman...

Страница 17: ...o wing screws off the side panel Tilt the panel outwards and lift it up Open the pellet container lid until it stops In this position it remains open Remove the two hexagonal screws Tilt the side pane...

Страница 18: ...container they can block the screw conveyor and damage the stove Note During any conversion work take particular care of your fingers and any panels and stove attachments Select soft bases to prevent...

Страница 19: ...ainst each other Place the correspondent flue pipe on the side Make sure that everything is tight Install the removed parts in reverse order Rear top connection R4 Remove the handle of the flue gas fl...

Страница 20: ...ting shield Note Operation of the stove without an assembled heat protectingshield is not allowed and leads to loss of warranty Place the 90 elbow with cleaning lid to the flue gas stack Make sure tha...

Страница 21: ...rated in either MANUAL or AUTOMATIC MODE In both MODES the current set heat output is used in AUTOMATIC MODE the heating times set at the stove can also be activated You can see whether the external d...

Страница 22: ...or clinker from the combustion chamber from the fire trough and the turning grid regularly Use the cleaning function to put the grid vertical Remove the clinker using the brush supplied and sweep the...

Страница 23: ...lean combustion air intake Note Only when the stove is cold You could vacuum out embers FIRE RISK If necessary please also clean the air intake with a hoover Clean pellet container Do not refill the c...

Страница 24: ...t and dust deposits in the fire and in the flue pipes and vacuum Note Accumulated fly ash in the flue gas channels may impair the performance of the stove and pose a safety risk Check bearings annuall...

Страница 25: ...see CLEANING and MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end...

Страница 26: ...se are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in...

Страница 27: ...ght Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YES...

Страница 28: ...fessional certified for that type of stove The installation is performed by a RIKA certified technician The stove is registered with RIKA by the RIKA specialist dealer importer on the RIKA Service Por...

Страница 29: ...uct life cycle In accordance with the European Directive 2012 19 EU Waste Electrical and Electronic Equipment WEEE and other local regulations RIKA supports the setup of take back systems and recyclin...

Страница 30: ......

Страница 31: ...31 EN 30...

Страница 32: ...ly valid one Subject to technical and visual changes as well as layout and printing errors 2020 RIKA Innovative Ofentechnik GmbH Z38569_Domo_Back_EN 16 07 2020 RIKA Innovative Ofentechnik GmbH M llerv...

Отзывы: