RIGOL
DS2000E User’s Guide
1-7
Probe Compensation
When the probe is used for the first time or when the probe compensation signal
does not match that shown in Figure 1-7, you should compensate the probe to match
the input channel of the oscilloscope. The non-compensated or poorly compensated
probe may cause measurement errors. The probe compensation procedures are as
follows:
1.
Perform Step 1, 2, 3, and 4 in "Function Inspection".
2.
Check the displayed waveforms and compare them with the following figures.
Figure 1-8 Probe Compensation
3.
Use a nonmetallic driver to adjust the low-frequency compensation adjustment
hole on the probe until the waveform is displayed as "Perfectly compensated" in
the figure above.
Over compensated Perfectly compensated Under compensated
Содержание DS2000E Series
Страница 1: ...RIGOL User s Guide DS2000E Series Digital Oscilloscope Oct 2017 RIGOL TECHNOLOGIES INC...
Страница 2: ......
Страница 22: ......
Страница 62: ......
Страница 72: ......
Страница 82: ......
Страница 198: ......
Страница 212: ......
Страница 238: ......
Страница 258: ......
Страница 261: ...Chapter 14 Remote Control RIGOL DS2000E User s Guide 14 3 3 4 5 6...
Страница 268: ......
Страница 283: ...Index RIGOL DS2000E User s Guide 3 X Y 3 4 X Y mode 6 37 Y Cursor 6 29 Y T 3 4...