background image

2

 

GENERAL INFORMATION

This manual, Code 20116337 - Rev. 9 (05/2022) 

comprises 12 pages.

GENERAL INFORMATION

RANGE

MODEL

CODE

RBS 200 2S

20116675

RBS 300 2S

20116335

RBS 430 2S

20117339

RBS 550 2S

20116587

RBS 800 2S

20132268

RBS 1000 2S

20132269

 

ACCESSORIES

For a complete list of accessories and details of their compatibil-

ity, refer to the Catalogue.

 

Dear heating engineer,

We would like to congratulate you on having recommended a 

R

 solar storage cylinder unit: a modern product that's ca-

pable of ensuring a high degree of reliability, efficiency, quality 

and safety.

While your technical skills and knowledge will certainly be more 

than sufficient, this booklet contains all the information that 

we have deemed necessary for the device's correct and easy in-

stallation.

 

Thank you again, and keep up the good work,

Riello S.p.A.

CONFORMITY

The 

R

 solar heaters comply with DIN 4753-3 and UNI EN 12897.

CONTENTS

ENGLISH

At the end of its life, the product should be 

not be disposed of as solid urban waste, but 

rather it should be handed over to a differen-

tiated waste collection centre.

The following symbols are used in this manual:

 

9

CAUTION! =

 Identifies actions that require caution and ad-

equate preparation.

 

0

STOP! =

 Identifies actions that you MUST NOT do.

GENERAL SAFETY INFORMATION

 

9

Check that the product is complete, undamaged and as or-

dered as soon as you receive it. Report any discrepancies or 

damage to the 

R

 dealer who sold it.

 

9

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to the 

highest standards in compliance with the instructions pro-

vided by 

R

 in this instruction manual, and that it con-

forms to all applicable laws and standards.

 

9

This product must only be used for the purpose for which it 

is designed and made, as specified by 

R

R

 declines 

all responsibility, contractual or other, for damage to prop-

erty or injury to persons or animals caused by improper in-

stallation, adjustment, maintenance or use.

 

9

The product must be serviced at least once a year. Servicing 

must be arranged in advance with the 

R

 Technical Assis-

tance Service.

 

9

All servicing and repairs must be performed by a qualified 

heating engineer.

 

9

If water leaks from the storage cylinder, turn off the water 

supply and contact 

R

’s Technical Assistance Service or a 

qualified heating engineer immediately.

 

9

If the product is not going to be used for an extended peri-

od of time, contact the manufacturer’s Technical Assistance 

Service to have at least the following operations performed:

 

− Close the shut-off cocks for the domestic hot water circuit

 

− Shut down the boiler connected to the storage cylinder 

as instructed in its own manual

 

− Switch the storage cylinder OFF at the control panel (if 

fitted) and at the mains power switch

 

− Drain the central heating circuit and domestic hot water 

circuit if there is any risk of freezing.

 

9

This instruction manual is an integral part of the product. It 

must be kept safe and must ALWAYS accompany the product, 

even if it is sold to another owner or transferred to another 

user or to another installation. If you lose this manual, or-

der a replacement immediately. Keep the product purchase 

documents to be presented to the 

R

 authorised Technical 

Assistance Service to request a service call under warranty.

 

9

Size the solar expansion tank so as to ensure complete ab-

sorption of the expansion of the fluid contained within the 

system, with reference to the prevailing regulations on the 

matter. In particular, consider fluid characteristics, consid-

erable fluctuation of service temperature and vapour that 

might be generated during solar collector stagnation stage. 

Proper size of expansion tank ensures setting off of all vol-

ume changes of the heat transfer fluid, avoiding excessive 

pressure increase. Limited pressure changes avoid reach-

ing safety valve opening pressure and the consequent fluid 

drainage.

This manual, Code
- Rev.
comprises
pages.

ENGLISH

General information

GENERAL INFORMATION

General Safety Information . . . . . . . . . . . . . . . . . . . . . . 2

2 Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Description of the appliance . . . . . . . . . . . . . . . . . . . . . 3

Identification  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

System layout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Technical specifications. . . . . . . . . . . . . . . . . . . . . . . . . 4

INSTALLATION

Unpacking the product . . . . . . . . . . . . . . . . . . . . . . . . . 6

Assembly of the insulation and the lining (models 

800 - 1000) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Place of installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

10 

Water quality requirements. . . . . . . . . . . . . . . . . . . . . . 6

11 

Water connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

TECHNICAL ASSISTANCE SERVICE

12 

Putting into service . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

13 

Temporary shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . .8

14 

Preparing for extended periods of disuse  . . . . . . . . . . .8

15 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

16 

Cleaning and removing internal components  . . . . . . . . 9

17 

Recycling and disposal  . . . . . . . . . . . . . . . . . . . . . . . . 10

END USER

18 Start-up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

19 

Temporary shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . .11

20 

Preparing for extended periods of disuse  . . . . . . . . . . .11

21 

External maintenance. . . . . . . . . . . . . . . . . . . . . . . . . .11

Содержание RBS 1000 2S

Страница 1: ...cod 20116337 rev 9 05 2022 RBS 200 300 430 550 2S RBS 800 1000 2S RBS 2S EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Страница 2: ...lified heating engineer 9If water leaks from the storage cylinder turn off the water supply and contact R s Technical Assistance Service or a qualified heating engineer immediately 9If the product is...

Страница 3: ...FC chlorofluorocarbons a flange is provided for easy cleaning and maintenance of the anti corrosion magnesium anode 4 IDENTIFICATION The R RBS 2S solar heaters can be identified by Data plate This lis...

Страница 4: ...1300 1 38 1 53 1 67 1 89 2 09 2 24 W K Energy class B B B B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Upper coil delivery temperatu...

Страница 5: ...n 10 with heater pre heated to the indicated temperature considering an increase of the domestic water temperature of 30 C between inlet and outlet according to EN 12897 Temperature of accumulation ta...

Страница 6: ...tooth open Apply the upper insulation 2 and the upper cover 5 in order to insert the cover exert a light and homogeneous pressure Close the interlocking flaps L completely which were previously left...

Страница 7: ...0 1 33 450 1 33 520 1 33 520 1 40 600 1 40 600 mm DF Flange internal diameter 130 130 130 130 130 130 mm A 171 171 208 207 75 75 mm B 243 253 329 348 289 289 mm C 403 393 427 443 428 421 mm D 598 693...

Страница 8: ...have been bled Make sure that the boiler and solar collectors connect ed to the system shut down correctly when their mains power switches are turned OFF Provided the above checks have been completed...

Страница 9: ...products petrol or triethylene INTERNAL CLEANING Removing and checking the first magnesium anode If the magnesium anode is fitted in the top of the storage cylin der remove the cover 1 and insulation...

Страница 10: ...s too low or too high Check the flow rate of the collector circuit Pressure is too low Check that circuit pressure is approxi mately 3 bar when cold There is lime scale or sludge in the cylinder Check...

Страница 11: ...switch if fitted 19 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with exter nal temperatures above 0 C set the heat...

Страница 12: ...lo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liabl...