FAMILY CONDENS IS E
16
47
THERMOREGULATION CURVE
INCLINATION (OTC) 2CH
-
2.5
40
10
48
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
0
50
TOUCH & GO FUNCTION
0 (OFF)
1 (ON)
1
51
HEAT REQUEST TYPE CH1 (circuit 1)
-
0
1
0
52
HEAT REQUEST TYPE CH2 (circuit 2)
-
0
1
0
61
DHW TEMP ANTI-FREEZE FUNCTION (ON)
°C
0
10
4
62
HEATING FUNCTION DELIVERY TEMP. (ON)
°C
0
10
6
63
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
6
65
EXTERNAL PROBE REACTIVITY
0 (VERY FAST) 255 (VERY SLOW)
20
85
SEMI-AUTOMATIC CHARGE
0 (DISABLED)
1 (ENABLED)
1
86
PRESSURE OF SEMI-
AUTOMATIC CHARGE (ON)
bar
0.4
1.0
0.6
87
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
1
90
VARIABLE SPEED PUMP
-
0
100
60
92
ENABLING OF POST-CIRCULATION
FROM DHW TO HEATING
-
0
1
0
93
DURATION OF POST-CIRCULATION
FROM DHW TO HEATING
-
1
255
5
94
PUMP IN CONTINUOUS MODE
ON FIRST CIRCUIT
-
0
1
0
95
PUMP IN CONTINUOUS MODE
ON SECOND CIRCUIT
-
0
1
0
* Output not available at present.
** The value is expressed on the display in rpm/100 (e.g. 3.700 = 37)
WARNING: certain default values may be different from those shown in the table, owing to the update level of the card.
Содержание FAMILY CONDENS 2.5
Страница 1: ...FAMILY CONDENS 2 5 3 0 3 5 IS E EN INSTALLER AND USER MANUAL HU TELEP T SI S HASZN LATI K ZIK NYV...
Страница 3: ...FAMILY CONDENS IS E 3...
Страница 68: ...FAMILY CONDENS IS E 68 M R AF G AC 9 11...
Страница 70: ...FAMILY CONDENS IS E 70 A C B D 1 2 3 4 5 7 9 11 12 13 10 F E 6 8 14 15...
Страница 86: ...FAMILY CONDENS IS E 86 fig 29 fig 32 fig 31 fig 30 B A C D...
Страница 87: ......
Страница 88: ...Cod 20120920 05 16 Ed 0...