FAMILY CONDENS IS E
30
ENGLISH
31
- Close the fuel and water taps of the heating and domestic hot wa-
ter system
In this case, the anti-freeze and anti-blocking systems are de-
activated. Drain the heating and domestic water system if there
is any risk of freezing.
The Riello Technical Assistance Centre is at your disposal if
you have any problems carrying out this procedure.
I -
Memory key
Press the
key to activate the Memory function - the display will
show the corresponding icon.
When the Memory key is activated, the boiler takes into account the
time that passes from the moment of firing; after 10 minutes, it in-
creases the stored outlet temperature by 5°C.
Memory repeats the cycle until the ambient temperature set on the
ambient thermostat is reached, or until the maximum permitted tem-
perature is reached.
Thanks to this automatic function, you can choose the lowest outlet
temperatures and, at the same time, minimise the times needed to
bring the room up to the required temperature.
J - InFO
When you press the key, the word InFO will appear on the display.
Rotate the encoder A to view - in sequence - the information de-
scribed below.
If the key is not pressed, after 10 seconds the system automatically
quits this function.
K - InFO list
Info 1
Displays the outdoor temperature measured by the external probe,
only if an external probe is connected
Info 2
Displays the system pressure value.
Info 3
Displays the set heating temperature
Содержание FAMILY CONDENS 2.5
Страница 1: ...FAMILY CONDENS 2 5 3 0 3 5 IS E EN INSTALLER AND USER MANUAL HU TELEP T SI S HASZN LATI K ZIK NYV...
Страница 3: ...FAMILY CONDENS IS E 3...
Страница 68: ...FAMILY CONDENS IS E 68 M R AF G AC 9 11...
Страница 70: ...FAMILY CONDENS IS E 70 A C B D 1 2 3 4 5 7 9 11 12 13 10 F E 6 8 14 15...
Страница 86: ...FAMILY CONDENS IS E 86 fig 29 fig 32 fig 31 fig 30 B A C D...
Страница 87: ......
Страница 88: ...Cod 20120920 05 16 Ed 0...