35
ENGLISH
7 START SCREEN
Upon ignition, the REC10 might:
- request the setting of the time and date (see paragraph
“12.1.1 Time
and date”).
- display the firmware version and require a button to be pressed in order
to continue.
By pressing the
“up”
and
“down”
keys it is possible to move the selection
of the functions in this order:
- PLANT
- STATE
- SET
- INFO
- MENU.
By pressing the
“ok”
key you access the settings of the selected function
(except for
PLANT
).
The
“back”
key is inactive (except for
PLANT
).
42
°C
MENU
STATE
SET
INFO
PLANT
HOT WATER TEMPERATURE
FRI
1.3
bar
18/05/2013
12:17
8 PLANT
This item does not represent any specifi c function.
Instead, it indicates the zone to which the data shown on the start screen
refer, and the zone to which the settings accessible via the other functions
refer.
The presence of one or more zones in addition to PLANT depends
upon the installation’s confi guration. For this reason, one or more of
the zones cited below may not be present in your confi guration, or may
be identifi ed with a diff erent name.
In order to change zones, highlight PLANT if necessary pressing the
“up”
and
“down”
keys.
Then, pressing the
“ok”
and
“back”
keys, it will be possible to select the
other zones in this sequence:
- PLANT
- MAIN ZONE
- ZONE 1
- ZONE 2.
The TIME AND DATE, LANGUAGE and BACKLIGHT settings are
independent of the selected zone.
The information contained in the INFO menu is independent of the selected
zone.
No domestic hot water parameters can be set if MAIN, ZONE 1 or ZONE
2 is selected.
9 STATE
The
STATE
function can be used to set the
BOILER
and
MAIN ZONE
operating modes.
To do this, it is necessary to highlight the desired entry using the
“up”
and
“down”
keys and then pressing
“ok”
to confi rm the selection.
Pressing
“back”
takes you back to the initial screen without making any
selection.
BOILER
MAIN ZONE
STATE
9.1
Boiler
This function can be selected in order to set the boiler’s status, by choosing
one of the following options:
- OFF
- SUMMER
- WINTER.
The highlighted status is that which is currently selected. In order to select a
diff erent status highlight it using the
“up”
and
“down”
keys and then press
“ok”
to confi rm the selection.
Once the selection has been validated, the display returns to the
STATE
screen.
Press
“back”
to return to the start screen without making any selection.
9.1.1
OFF
HOT WATER ONLY
HEATING AND HOT WATER
BOILER
OFF
If
OFF
is selected, the system shuts off .
The electrical supply and the fuel supply remain active.
9.1.2
Summer
If
SUMMER
is selected, the system produces domestic hot water.
Heating is not enabled.
9.1.3
Winter
If
WINTER
is selected, the system produces domestic hot water and
activates the heating function.
9.2
Main zone
Selecting this function allows you to set the main zone’s status, by choosing
one of the following options:
- if the heating programming timing is not enabled:
- ZONE ON
- ZONE OFF
ZONE ON
ZONE OFF
MAIN
- if the heating programming timing is enabled:
- AUTO
- MANUAL
- HEAT OFF.
MAIN
AUTO
MANUAL
HEAT OFF
In order to select a different status highlight it using the
“up”
and
“down”
keys and confirm the selection by pressing
“ok”
.
Once the selection has been validated, the display returns to the
STATE
screen.
Press
“back”
to return to the
STATE
screen without making any selection.