3312
1
GB
ENGLISH
TECHNICAL DATA
For gas family 3 (LPG) ask for separate kit.
O
The burner meets protection level of IP X0D (IP 40) as EN 60529.
O
The burner is approved for intermittent operation as per Directive EN 676.
O
CE marking in accordance with Gas Appliance Directive 90/396/EEC; PIN 0063AP6680.
O
Burner with CE marking in conformity with EC Directives: EMC 2004/108/EEC, Low Voltage
2006/95/EC and Machines 2006/42/EC.
O
Gas train according to EN 676.
NOTES
– The grommet (6) supplied with the burner, must be fitted to the same side of the gas train.
– After having installed the burner verify the access to the fixing screws of the cover.
If necessary replace them with the fixing screws (7, fig. 1) supplied as equipment.
TYPE
587M
Thermal power
12 / 23
58 kW
–
10.000 / 20.000
50.000 kcal/h
Natural gas
(Family 2)
Pci
8
12 kWh/m
3
–
7.000
10.340 kcal/m
3
Pressure
min. 10 mbar
–
max. 40 mbar
Electrical supply
Single phase,
230 V ± 10% ~ 50Hz
Motor
Run current 0.75 A
-
2800 rpm
-
294 rad/s
Capacitor
2
F
Ignition transformer
primary 230 V / 0.2 A
–
secondary 8 kV
Absorbed electrical power
0.15 kW
COUNTRY
IT - AT - GR - DK - SE
GB - IE
FR
DE
LU - PL
GAS CATEGORY
II2H3B/P
II2H3P
II2Er3P
II2ELL3B/P
II2E3B/P
1
– Air damper opening motor
2
– Air dampers
3
– Capacitor
4
– Motor
5
– Air pressure switch
6
– Grommet
7
– Hood fixing screw
8
– 6 pole socket for gas train
9
– 4 pole socket for 2
nd
stage
10
– Control box
11
– Lockout lamp with reset button
1
6
2
7
9
10
11
D7389
5
4
3
Fig. 1
8