![Riello 20187643 Скачать руководство пользователя страница 108](http://html1.mh-extra.com/html/riello/20187643/20187643_installer-and-user-manual_1459307108.webp)
108
FAMILY
D
C
A
B
F
E
2
1
3
4
5
7
6
8
9
10
15
12
11
14
13
2
15.3
EN
Residual head of circulator (Fig. 3)
A
B
C
Residual head (mbar)
Flow rate (l/h)
7-metre circulator (factory setted)
HU
A keringető maradék fejmagassága (
3. ábra)
A
B
C
Maradék emelőnyomás
(mbar)
Hozam (l/h)
7 méteres keringtető szivattyú (gyári
beállítás)
RO
Presiune reziduală a pompei de circulaţie (
Fig. 3)
A
B
C
Presiune reziduală
(mbari)
Debit (l/h)
Pompă de circulaţie la 7 m (setată în
fabrică)
DE
Restförderhöhe der Umlaufpumpe (Abb. 3)
A
B
C
Restförderhöhe (mbar) Durchsatz (l/h) 7-Meter Umlaufpumpe (Werkseinstellung)
3
B
A
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
Pr
eva
le
nz
a
[m
ba
r]
Portata impianto [l/h]
100
85 (default)
60
41
C
15.2
[EN] - Hydraulic circuit
[HU] - Hidraulikus kör
[RO] - Circuit hidraulic
[DE] - Wasserkreislauf
A
Heating delivery
Fűtés előremenő
Tur încălzire
Heizungsvorlauf
B
Heating return
Fűtési visszatérő
Retur încălzire
Heizungsrücklauf
C
Water tank delivery
Víztartály előremenő
Livrare rezervor de apă
Boiler-Vorlauf
D
Water tank return
Víztartály visszatérő
Retur rezervor de apă
Boiler-Rücklauf
E
Cold water inlet
Hideg víz-bemenet
Intrare apă rece
Kaltwassereingang
F
Hot water outlet
Meleg víz-kimenet
Ieşire apă caldă
Warmwasserausgang
1
Safety valve
Biztonsági szelep
Supapă de siguranţă
Sicherheitsventil
2
Drain valve
Leeresztő szelep
Supapă de evacuare
Ablassventil
3
Automatic by-pass
Automatikus by-pass
By-pass automat
Automatischer Bypass
4
Pressure transducer
Nyomástranszduktor
Traductor de presiune
Druckaufnehmer
5
Manual air vent valve
Manuális légtelenítő szelep
Vană de evacuare aer manuală
Manuelles Entlüftungsventil
6
Delivery NTC probe
Előremenő NTC érzékelő
Sondă NTC tur
Vorlauf-NTC-Fühler
7
Limit thermostat
Határoló termosztát
Termostat limită
Grenzthermostat
8
Primary heat exchanger
Elsődleges hőcserélő
Schimbător principal de căldură
Primärwärmetauscher
9
Return NTC probe
Visszatérő NTC érzékelő
Sondă NTC retur
Rücklauf-NTC-Fühler
10
Expansion vessel
Tágulási tartály
Vas de expansiune
Ausdehnungsgefäß
11
Lower air vent valve
Alsó légtelenítő szelep
Supapă inferioară de aerisire
Unteres Entlüftungsventil
12
Circulator
Keringtető szivattyú
Pompă de circulaţie
Umlaufpumpe
13
Water gauge
Hidrométer
Hidrometru
Hydrometer
14
Three-way valve
Háromutas szelep
Vană cu trei căi
3-Wege-Ventil
15
Water tank (available by request)
Víztartály (kérésre)
Rezervor de apă (disponibil la cerere)
Boiler (auf Anfrage verfügbar)
[EN] - Residual head of circulator
The boiler is equipped with a high efficiency
modulating circulator already hydraulically
and electrically connected, whose useful avail
-
able performance is indicated in the graph
.
The modulation is managed by the board
through the PUMP DUTY CYCLE
-
access
level INSTALLER.The circulator is factory set
with discharge head of 7 meters. The boiler is
equipped with an anti-blocking system which
starts up an operation cycle after every 24
hours of disuse in any operating status.
b
The "anti-locking" function is
only activated when the boiler
is electrically powered.
a
It is strictly forbidden to operate the
circulator without water
.
Where there is the need to use a different
curve, the desired level can be selected on
the circulator
.
Variable speed circulator
The modulating circulator function (applica
-
ble only to the boiler circulator and not to the
circulators of any external devices connected
(e.g. booster circulator)) is only active in the
heating function. The circulator always oper
-
ates at maximum speed when switching the
three-way to DHW. Through the PUMP DUTY
CYCLE parameter it is possible to choose
between
:
1 - VARIABLE SPEED CIRCULATOR WITH
PROPORTIONAL MODE (41 <= PUMP
DUTY CYCLE <= 100):
the boiler board
determines which flow rate curve to adopt
according to the instantaneous power deliv
-
ered by the boiler
.
2 - VARIABLE SPEED CIRCULATOR WITH
CONSTANT
∆T
MODE (2 <= PUMP
DUTY CYCLE <= 40):
the installer sets the
∆T value to be maintained between outlet
and return (e.g .:by entering a value = 10,
the circulator speed will change to achieve
a system flow rate with the aim of maintain
-
ing the ∆T of 10°C upstream and down
-
stream of the exchanger)
.
3 - CIRCULATOR IN MAXIMUM FIXED
SPEED MODE (PUMP DUTY CYCLE =
1):
the circulator, when activated, always
operates at maximum speed. Used on
systems with high pressure drop where
it is necessary to make the most of the
boiler discharge head in order to ensure
sufficient circulation (system flow rate at
maximum speed less than 600 litres per
hour)
.
Used in the presence of hydraulic separa
-
tors with high flow rates in the downstream
circuit. Operationally
:
enter the PUMP DUTY CYCLE parameter
set the value = 1
4 - EXCEPTIONAL USE OF A STANDARD
NON-SPEED ADJUSTABLE CIRCULA-
TOR (PUMP DUTY CYCLE = 0):
mode
used in exceptional cases in which a tra
-
ditional UPS circulator is to be used in the
boiler.
EN
CONFIGURATIONS RECOMMENDED BY THE MANUFACTURER
OUTDOOR TEMPERATURE
SENSOR YES
(THERMOREGULATION)
OUTDOOR TEMPERATURE
SENSOR
(NO THERMOREGULATION)
LOW
TEMPERATURE
(floor)
ΔT constant
(5 ≤ PUMP DUTY CYCLE ≤ 7)
PROPORTIONAL
(PUMP DUTY CYCLE = 85)
HIGH
TEMPERATURE
(radiators without
thermostatic valves)
ΔT constant
(15 ≤ PUMP DUTY CYCLE ≤ 20)
PROPORTIONAL
(PUMP DUTY CYCLE = 85)
HIGH
TEMPERATURE
(radiators with
thermostatic valves)
ΔT constant
(15 ≤ PUMP DUTY CYCLE ≤ 20)
PROPORTIONAL
(PUMP DUTY CYCLE = 60)
Содержание 20187643
Страница 116: ...Cod 20187602 06 22 Ed 6...