GENERAl INfORMAtION

1

 

GENERAL INFORMATION

1.1

 

General Notices

When you get the product, check immediately that the con-
tents are all present and undamaged. Contact the dealer 

R

 if you notice any problems.

The product' s installation must be carried out by an au-
thorised company that will issue a declaration of the instal-
lation's conformity to the product's owner once the work 
has been completed, indicating that the work has been car-
ried out in accordance with the standards of good practice, 
current National and Local regulations, and the indications 
provided by 

R

 in the instruction booklet accompanying 

the device.

The R32 refrigerant gas is slightly inflammable and odour-
less. Carefully read the safety data sheet available from the 
dealer and see table "Minimum floor area for ceiling instal-
lation" 

p. 8.

The product must be used for its intended purpose, as stat-
ed by 

R

 for which it has been expressly manufactured. 

R

 shall bear no responsibility, whether of a contractual 

or non-contractual nature, for any damage caused to peo-
ple, animals, or property due to incorrect installation, ad-
justments, or maintenance, or improper use.

Suitable clothing, instrumentation, and accident-preven-
tion devices must be utilized during the installation and/
or maintenance operations. 

R

 shall bear no responsi-

bility for any failure to comply with current safety and acci-
dent-prevention regulations.

During installation and/or service operations, keep the area 
around the unit tidy and clean.

Comply with the legislation in force on the country of de-
ployment with regard to the use and disposal of packaging, 
of cleaning and maintenance products and for the man-
agement of the unit's decommissioning.

Any repair and maintenance interventions must be carried 
out by 

R

 Technical Support Service, in accordance with 

the provisions contained in this publication. Do not modify 
or tamper with the unit as dangerous situations may arise 
and the unit manufacturer will not be liable for any damage 
caused.

In the event of any functional anomalies or fluid leaks, set 
the system's main switch to its "off" position. Promptly con-
tact your local 

R

 Technical Support Service, and do not 

perform any interventions upon the device on your own.

The units contain refrigerant gas: operate carefully so as to 
avoid damaging the gas circuit and the fin bank.

Any gas leaks indoors can generate toxic gases if they come 
into contact with naked flames or high temperature bodies, 
in case of leaks, please air the rooms thoroughly.

Do not place any inflammable object (spray cans) within a 1 
metre radius from the air expulsion.

According to EU Regulation no. 517/2014 regarding certain 
fluorinated greenhouse gases, the total amount of refrig-
erant contained within the installed system must be indi-
cated. This information can be found on the unit technical 
data plate.

This unit contains fluorinated greenhouse gases covered 
by the Kyoto protocol. Maintenance and disposal activities 
must be carried out exclusively by skilled personnel.

This booklet is an integral part of the device, and must 
therefore be carefully preserved, and must ALWAYS accom-
pany it, even in the event that it is sold to another Owner 
or User, or is transferred to another system. If it is damaged 
or lost, another copy can be requested to 

R

 Technical 

Support Service in your Area.

1.2

  Safety precautions

It should be noted that the use of products that utilize elec-
tric energy requires certain essential safety regulations to be re-
spected, including the following:

 

0

Do not allow children or unassisted disabled people to use 
the unit.

 

0

Do not touch the unit while barefoot and/or partially wet.

 

0

Do not spray or throw water directly on the unit.

 

0

It is strictly forbidden to touch the coil fins, the moving parts, 
to place any body parts between them, or to insert pointy 
objects into the grilles.

 

0

It is forbidden to perform any technical interventions or 
cleaning operations before having disconnected the de-
vice from its electrical power supply, by setting the system's 
main switch to its "OFF" position.

 

0

It is forbidden to modify the safety or regulation devices 
without the authorisation of the manufacturer.

 

0

Do not pull, detach or twist the electrical wires coming out 
of the unit, even when the unit is disconnected from the 
power grid.

 

0

The packing material must not be disposed of in the sur-
rounding environment and must be kept out of children 
reach, as it can be dangerous. It must be disposed of ac-
cording to the regulations in force.

Содержание 20159404

Страница 1: ...cod Doc 0093022 rev 0 04 2019 AMS P SERIES R32 EN INSTALLATION AND TECHNICAL SERVICE INSTRUCTIONS...

Страница 2: ...s correct and easy installation Thank you again and keep up the good work RIELLO RANGE Model Code AMS 100 P 20159404 AMS 125 P 20159405 AMS 140 P 20159406 ACCESSORIES For the complete list of accessor...

Страница 3: ...NCE p 22 3 1 Preparation for first commissioning p 22 3 2 Putting into service p 23 3 3 Temporary shutdown p 23 3 4 Stop for an extended period of time p 23 3 5 Ordinary maintenance p 23 3 6 Extraordi...

Страница 4: ...vice and do not perform any interventions upon the device on your own 9 The units contain refrigerant gas operate carefully so as to avoid damaging the gas circuit and the fin bank 9 Any gas leaks ind...

Страница 5: ...r transmitting the detected value to the control panel in order to control the operation of the outdoor unit and regulate the room temperature 9 Safety device replacement must be carried out by R Tech...

Страница 6: ...eed 700 750 800 rpm Cooling sound levels Superminimum sound pressure 37 38 39 dB A Minimum sound pressure 41 43 44 dB A Medium sound pressure 43 45 46 dB A Maximum sound pressure 47 48 49 dB A Maximum...

Страница 7: ...truction s book for the installer and for the Technical Service in English user instruction booklet in Italian user instruction booklet in English Warranty Spare parts labels contact sheets It is also...

Страница 8: ...nstalled in rooms with a minimum floor area as indicated in the following table depending on the total refrigerant charge of the system given by the sum of the factory charge of the outdoor unit and i...

Страница 9: ...ATION 150 10 80 IN THE CEILING INSTALLATION 1 false ceiling 150 10 80 1 1 HIGH SPACING DISTANCE 2300 2 8 Installation on old systems or systems in need of upgrading When R AMS P is installed on old sy...

Страница 10: ...ssure down do not continue installation and check for leakage inside the unit 9 Contact R Technical Support Service Horizontal ceiling mounting position the support rods and fix them properly to the b...

Страница 11: ...of installation of the unit center the unit over the opening 10 15 10 15 regulate the unit s position so as to create a slope towards the condensation drainage tighten the fastening nut 9 Seal the nut...

Страница 12: ...tion 9 52 mm Gas line connection 15 88 mm 9 For indications concerning distances and differences in height of connection pipes refer to the matching outdoor unit manual 9 Use clean hoses Make sure the...

Страница 13: ...s 9 Use equipment suitable for the system refrigerant 9 Avoid using the refrigerant oil on the external part of the flaring 9 Avoid proximity to sources of ignition in continuous op eration open flame...

Страница 14: ...scharge 1 1 Model 100 125 140 Connections Condensate discharge attachment VP25 mm Connections 1 Hose clamp 2 Condensate discharge pipe 3 Drainage pipe 1 2 3 connect a rubber drainage pipe direct it to...

Страница 15: ...metal sheet connect a circular duct to the prepared connection seal the connection 9 When removing the pre cut sheet take special care not to damage the internal components 9 The edges of the pre cut...

Страница 16: ...ilable BM1 5 Cooling Heating Cooling only available BM1 6 BM1 7 BM1 8 ON ON OFF ON ON ON OFF OFF ON ON CN24 SW1 DISPLAY BOARD CN4 ON OFF MODEL OFF ON OFF ON OFF OFF OFF ON Cooling Heating OFF ON OFF O...

Страница 17: ...fasten the grid repeat for all elements 1 Electrical box 2 Connections input 1 2 1 Fixing screws 2 Electric panel access panel 3 Terminal blocks 1 1 2 3 unscrew the fastening screws remove the electri...

Страница 18: ...t all components by performing the described operations in reverse order Mandatory items connect the device to a properly functioning earthing sys tem for any electrical intervention always refer to t...

Страница 19: ...ou remove the batteries all settings in the remote control will be deleted Fit the new batteries and reprogram 9 Do not dispose of old batteries in the environment Always take them to the suitable con...

Страница 20: ...witches the temperature scale from Celsius to Fahrenheit and vice versa Gives access to Timer ON settings Gives access to Timer OFF settings It gives access to current time change settings It increase...

Страница 21: ...s enabled Available for Cassette unit only Horizontal deflector position Vertical deflector position Not available for Cassette unit Climatic settings 1 Detected ambient humidity 2 Required temperatur...

Страница 22: ...del setting do not change BM1 4 It enables and disables the Roomcard function OFF disabled factory setting if the clean contact Roomcard opens the unit will turn off automatically Remote control can b...

Страница 23: ...ic conditions and not for usual operation Checks during and after the first commissioning After starting the device check that the current consumed by the compressor is less than the maximum permitted...

Страница 24: ...he annual maintenance plan includes the following checks power supply voltage electric connection tightening status of cooling and hydraulic joint condensate tray cleaning electric absorption 3 6 Extr...

Страница 25: ...resets after problem resolution 2 E2 Exchanger probe fault 4 E4 Microprocessor malfunction 7 E7 Communication error between indoor unit and outdoor unit 8 E8 Communication error between unit and contr...

Страница 26: ...and disposal 4 DISPOSAL Packaging materials shall be disposed of separately so as to re cover and recycle them At the end of its service life the device shall be disposed of according to the existing...

Страница 27: ...39 0442 630111 fax 39 0442 630371 www riello it As the manufacturer is constantly improving its products the aesthetic or dimensional features the technical data the equipment and accessories indicat...

Отзывы: