6.3 Operation
The RW motor-gearboxes are usually used in automated systems.
Operation is possible with a manual control (MC) and/or other Ridder control components, which
are compatible with (if applicable) “Automatic Control-Systems” (ACS).
Refer to the Ridder catalog or website
for more information. Always refer to the related
information and manuals (ACS and control components).
6.4 Safety functions and stop functions
The RW motor-gearbox has the safety functions and stop functions that follow:
1.
Stop at an adjusted end position when a duty switch is operated
2.
Stop when a safety switch is operated if a duty switch not disconnects
3.
Stop when not operated and then lock the output shaft because of a self-braking worm-gear
transmission
4.
Thermal-overload protection of the electric motor with a built-in PTO switch.
7. COMMISSIONING INSTRUCTIONS
The commissioning is only permitted to approved personnel.
7.1 Commissioning - Conditions and starting points
•
It is important to fully know the working principle of the RLS/RSU limit-switch system in §7.2.
•
After that obey the procedure in §7.3.
Do not go across the limits of the system. This prevents damage or
injury.
Before the system is put into operation, the installer must always
make sure that the limit switch is correctly adjusted.
Make sure that there is no blockage of the system before the limit-
switch system is adjusted. This prevents damage or injury.