T
echnical
B
ulletin
PAGE: 50/66
Reissued: 8-Apr-05
Model:
Martini-P1
Date:
2-Mar-05
No.:
RG126002a
Attaching the Finisher to the Machine
1. Attach the sponge strip [A] (this is supplied with the finisher).
NOTE:
If you will install the cover interposer tray with a finisher that was installed on
the machine before this time, remove the strip from the finisher and attach it to
the cover interposer tray.
2. Attach the guide plate [B] (removed from the finisher) to the cover interposer
(2 screws).
NOTE:
Make sure to use the two small tapping screws supplied with the machine, and
not the machine screws that you removed from the finisher with the guide
plate.
3. Release the lock lever [C] (1 screw).
4. Lower the transport guide plate [D].
5. Slowly push the finisher against the side of the machine until the brackets [E] go into
the slots.
IMPORTANT
:
Do the above step carefully. Do not bend the entrance guide plates.
Bent guide plates could cause a blockage for paper transport between the
finisher and printer.
6. Attach the lock lever [C] (1 screw).
7. Lift the transport guide plate [D] to close it.
8. Connect the connector [E] into the printer.
B470I005.WMF
[A]
[B]
[C]
[F]
[D]
[E]