T
echnical
B
ulletin
PAGE: 14/66
Reissued: 8-Apr-05
Model:
Martini-P1
Date:
2-Mar-05
No.:
RG126002a
Removing and Filling the Development Unit
IMPORTANT:
Before you begin,
remove the toner bottle
if it is installed.
Note:
If the toner bottle is in the machine when you do this procedure, the toner bottle
holder can be damaged.
1. Remove the shutter cover [A] of the toner supply unit (1 screw).
2. Remove the lock screw [B] from the toner bottle open/close bracket.
3. Remove the shipping tape [C] if it is still there.
4. Pull the toner bottle holder and swing it to the right.
5. Remove the face plate [E] of the development
unit (1 knob, 2 screws).
B064I302.WMF
[E]
[B]
[A]
[C]
[D]