Initializing the Drum Settings
You must do SP2963 (Installation Mode) to 1) Initialize the developer and do a forced
toner supply to the development unit, and 2) Initialize the auto process control settings.
•
You must open the front door before you switch the machine on. If you do this, the
machine does not do the short automatic process control procedure, which is usually
done after the machine power is turned on.
•
SP2963 must be done before you do sample copying or test printing.
•
If you do not press “Enter” in Step 6, the auto process control items (potential sensor
calibration, Vsg, Vref, etc.) will not initialize correctly.
1. Open the front door.
2. Connect the power cord.
3. Turn the main power switch on.
4. Go into SP mode.
•
Press the “Up/Down arrow” keys together for about 5 seconds, then press the
“Enter” key.
5. Close the front door.
6. Do SP2963.
•
Input the Developer Lot No. with the key display, then press “Enter”.
Approximately four minutes is necessary to initialize toner supply and the auto process
control settings.
7. Press “End” to go out of the SP mode.
8. Attach the applicable decals (supplied with the machine) to the paper trays.
9. Check the print quality and machine operation.
IMPORTANT
•
At installation, use SP2963 to enter the lot number, initialize the developer, and to
force toner supply to the toner hopper.
•
After you replace developer in a machine that has been already installed, do not
use SP2963; use SP2801 (TD Sensor Initial Setting) instead to enter the lot number
and initialize the TD sensor.