Code
Level
Details
544
A
High Temperature Error (Hardware)
The machine checks the CPU port at 50 ms intervals.
This SC is displayed if the CPU port was detected to be LOW for 4 consecutive
times.
• The PSU is defective (triac has short-circuited).
• The fusing unit is defective.
• The main board is defective.
• Replace the PSU.
• Replace the fusing unit.
• Replace the main board.
• After solving the problem, the service technician must execute
[FusingSCReset]. Otherwise, the machine will continue to issue this SC code
and cannot be operated. (page 64 "Executing Fusing SC Reset")
Code
Level
Details
545
A
Fuser Full Heater Error
The heating element of the fusing lamp remained at full power for more than 7
sec. (100 V) or 9 sec. (200 V) after the reload temperature was detected.
The machine checks for this error during standby, energy save, after reload, or
when the fusing unit is not rotating.
• The thermistor is deformed or loose.
• The fusing lamp is damaged.
• The overheat prevention device is activated.
• Check the fusing thermistor.
• Check the fusing lamp.
• After solving the problem, the service technician must execute
[FusingSCReset]. Otherwise, the machine will continue to issue this SC code
and cannot be operated. (page 64 "Executing Fusing SC Reset")
5. Troubleshooting
72
Содержание M0AE-17
Страница 1: ...Model Rev P1 MF1 Machine Codes SFP M290 M0AF MFP M291 M0AE Field Service Manual January 2016 ...
Страница 2: ......
Страница 18: ...16 ...
Страница 24: ...1 Product Information 22 ...
Страница 26: ...2 Installation and Preventive Maintenance 24 ...
Страница 49: ...2 Remove the HVP A x4 x1 Electrical Components 47 ...
Страница 56: ...3 Replacement and Adjustment 54 ...
Страница 79: ...6 Energy Saving Energy Save Energy Saving Modes 77 ...
Страница 80: ...MEMO 78 ...
Страница 81: ...MEMO 79 ...
Страница 82: ...MEMO 80 EN ...