SC6xx: Communication Errors
Code
Level
Details
688
D
No CTL_PRREQ_N Signal
Paper failed to feed after the machine has reached the reload temperature,
because the main board did not issue a PRREQ signal.
• The main board harness connector is loose, broken, or defective.
• The main board is defective.
• Check the main board harness connector.
• Replace the main board.
SC10xx: Others
Code
Level
Details
1001
D
Scan Motor Error
Scanner calibration failed (scanner cannot find the home position).
• Cycle the power OFF/ON.
• Check the connection.
• Replace the scanner unit.
5. Troubleshooting
74
Содержание M0AE-17
Страница 1: ...Model Rev P1 MF1 Machine Codes SFP M290 M0AF MFP M291 M0AE Field Service Manual January 2016 ...
Страница 2: ......
Страница 18: ...16 ...
Страница 24: ...1 Product Information 22 ...
Страница 26: ...2 Installation and Preventive Maintenance 24 ...
Страница 49: ...2 Remove the HVP A x4 x1 Electrical Components 47 ...
Страница 56: ...3 Replacement and Adjustment 54 ...
Страница 79: ...6 Energy Saving Energy Save Energy Saving Modes 77 ...
Страница 80: ...MEMO 78 ...
Страница 81: ...MEMO 79 ...
Страница 82: ...MEMO 80 EN ...