Code
Level
Details
542
A
Fusing Reload Temperature Error
After starting up or during operation, the reload (operating) temperature cannot
be reached.
• The fusing thermistor is deformed or out of position.
• The fusing lamp harness is loose, broken, or defective.
• The fusing unit is defective.
• The power voltage is not correct.
• Check the power voltage.
• Check the fusing unit thermistor.
• Check the fusing lamp.
• Replace the fusing unit.
• After solving the problem, the service technician must execute
[FusingSCReset]. Otherwise, the machine will continue to issue this SC code
and cannot be operated. (page 64 "Executing Fusing SC Reset")
Code
Level
Details
543
A
High Temperature Error (Software)
The temperature inside the fusing unit exceeded 235°C for more than 0.5 sec.
This SC is displayed if the error is detected 10 times or more.
However, the machine does not check for this error during low power mode,
sleep mode, cover open, or when the fusing lamp relay is OFF due to
malfunctions.
• The PSU is defective (triac has short-circuited).
• The main board is defective.
• Replace the main board.
• After solving the problem, the service technician must execute
[FusingSCReset]. Otherwise, the machine will continue to issue this SC code
and cannot be operated. (page 64 "Executing Fusing SC Reset")
Service Calls
71
Содержание M0AE-17
Страница 1: ...Model Rev P1 MF1 Machine Codes SFP M290 M0AF MFP M291 M0AE Field Service Manual January 2016 ...
Страница 2: ......
Страница 18: ...16 ...
Страница 24: ...1 Product Information 22 ...
Страница 26: ...2 Installation and Preventive Maintenance 24 ...
Страница 49: ...2 Remove the HVP A x4 x1 Electrical Components 47 ...
Страница 56: ...3 Replacement and Adjustment 54 ...
Страница 79: ...6 Energy Saving Energy Save Energy Saving Modes 77 ...
Страница 80: ...MEMO 78 ...
Страница 81: ...MEMO 79 ...
Страница 82: ...MEMO 80 EN ...