SC5xx: Main Motor Errors, Fusing Errors
Code
Level
Details
501
D
Plate Action Error
The status of the bottom plate position sensor does not change even though 2
secs or more have lapsed after the bottom plate lift clutch is turned ON.
This SC is displayed if the error is detected 3 times.
• The bottom plate lift clutch is loose or defective.
• The bottom plate position sensor is loose or defective.
• Cycle the power OFF/ON.
• Replace the bottom plate lift clutch.
• Replace the bottom plate position sensor.
• Replace any harnesses connected to the bottom plate lift clutch or bottom
plate position sensor.
Code
Level
Details
520
D
Main Motor Error
• The machine failed to detect a lock signal within 550 ms after the main
motor was turned on.
• The machine failed to detect a lock release signal with 2 sec. after the main
motor was turned off.
• This SC is displayed if a lock signal cannot be detected for 8 consecutive
times.
• The AIO is defective.
• The main motor is defective.
• Cycle the power OFF/ON.
• Check the areas around motor and main drive train for any physical
obstruction such as paper scraps.
• Clean the main motor drive train.
• Replace the AIO.
• Replace the main motor.
Service Calls
69
Содержание M0AE-17
Страница 1: ...Model Rev P1 MF1 Machine Codes SFP M290 M0AF MFP M291 M0AE Field Service Manual January 2016 ...
Страница 2: ......
Страница 18: ...16 ...
Страница 24: ...1 Product Information 22 ...
Страница 26: ...2 Installation and Preventive Maintenance 24 ...
Страница 49: ...2 Remove the HVP A x4 x1 Electrical Components 47 ...
Страница 56: ...3 Replacement and Adjustment 54 ...
Страница 79: ...6 Energy Saving Energy Save Energy Saving Modes 77 ...
Страница 80: ...MEMO 78 ...
Страница 81: ...MEMO 79 ...
Страница 82: ...MEMO 80 EN ...