3.
From the Output Check Items list, select [FusingSCReset].
4.
Click [On].
SC Tables
SC Table Key
SC codes are assigned a level of severity (A, B, C, D) based on the table below. These letters appear in
the 3rd column of the SC tables below.
Level
Definition/ Reset Procedure
A
This is a fatal error.
The machine is disabled due to a problem in the fusing unit. The operator cannot
operate the machine.
• The machine requires immediate servicing by a service technician.
• After solving the problem, [FusingSCReset] must be executed to release the
machine for normal operation.
B
Only the function that uses the defective unit is disabled. The SC code is shown in the
message on the Status Panel.
• Cycle the power OFF/ON.
Service Calls
65