SC
[Level]
Symptom
Possible Cause/Required Action
234
[C]
FGATE: On error [M]
The PFGATE register of GAVD
does not assert within 5
seconds after processing the
image in normal job or MUSIC
for [M] started.
Same as SC 230
235
[C]
FGATE: Off error [M]
• The PFGATE ON signal
still asserts within 5
seconds after processing
the image in normal job
or MUSIC for [M] ends.
• The PFGATE ON signal
still asserts when the next
job starts.
Same as SC 231
236
[C]
FGATE: On error [C]
The PFGATE register of GAVD
does not assert within 5
seconds after processing the
image in normal job or MUSIC
for [C] started.
Same as SC 230
237
[C]
FGATE: Off error [C]
• The PFGATE ON signal
still asserts within 5
seconds after processing
the image in normal job
or MUSIC for [C] ends.
• The PFGATE ON signal
still asserts when the next
job starts.
Same as SC 231
240
[D]
LDB error [K]
The EGB detects LDB error a
few times consecutively when
• Defective LDB
1. Replace the LDB.
4. Troubleshooting