The value displayed on the LCD is different from
these SP's values. For example, "4%" on the
LCD actually means 20 %.
2921
[S: HH SP: 2nd] Smaller than A5 HH Special paper, 2nd side
2921 001
T2 Switch Timing
*EGB
[0 to 200 / 15 / 1 mm/step]
2921 002
T2 Correction
*EGB
[0 to 1275 / 0 / 5%/step]
The value displayed on the LCD is different from
these SP's values. For example, "20%" on the LCD
actually means 100%.
2930
[Separa. : LE: HH] Separation Voltage: Correction for HH Humidity at the Leading Edge
(Paper Type, Process Speed, [Color]) Paper Type -> Normal, Thin
Process Speed -> LS: Low speed, RS: Regular speed
• The value displayed on the LCD is different from these SP's values. For example,
"20%" on the LCD actually means 100%.
2930 001
Normal: RS: [K]
*EGB
[0 to 400 / 200 / 5%/step]
2930 002
Normal: RS: [FC]
*EGB
2930 003
Normal: LS: [K]
*EGB
2930 004
Normal: LS: [FC]
*EGB
2930 005
Normal 2: RS: [K]
*EGB
2930 006
Normal 2: RS: [FC]
*EGB
2930 007
Normal 2: LS: [K]
*EGB
2930 008
Normal 2: LS: [FC]
*EGB
2930 009
Thin: RS: [K]
*EGB
2930 010
Thin: RS: [FC]
*EGB
2930 011
Thin: LS: [K]
*EGB
2930 012
Thin: LS: [FC]
*EGB
Service Mode Table
223
5
Содержание G-P3
Страница 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Страница 11: ...10...
Страница 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Страница 91: ...3 Replacement and Adjustment 90 3...
Страница 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Страница 337: ...5 Service Tables 336 5...
Страница 411: ...MEMO 410...
Страница 412: ...MEMO 411...
Страница 413: ...MEMO 412...