3102 001
Change Value: [K]
*EGB
Displays the toner amount change of the ID sensor
pattern for each color.
[-1.000 to 1.000 / 0 / 0.001 mg/cm
2
/step]
3102 002
Change Value: [M]
*EGB
3102 003
Change Value: [C]
*EGB
3102 004
Change Value: [Y]
*EGB
3103
[P. Sensor Patt.] ID Sensor Pattern Setting ([Color]) DFU
3103 001
Pot.Corr.Val: [K]
*EGB
Stores the delta Vcnt (current Vcnt - initial Vcnt)
value for each color.
[-500 to 500 / 0 / 1 V/step]
3103 002
Pot.Corr.Val: [M]
*EGB
3103 003
Pot.Corr.Val: [C]
*EGB
3103 004
Pot.Corr.Val: [Y]
*EGB
3104
[P. Sensor Patt.] ID Sensor Pattern Setting ([Color]) DFU
3104 001
m/a Corr.Step:[K]
*EGB
Adjusts the change amount of toner at the density
change rate of the ID sensor pattern.
[0 to 0.250 / 0.015 / 0.001 mg/cm
2
/step]
3104 002
m/a Corr.Step:[M]
*EGB
3104 003
m/a Corr.Step:[C]
*EGB
3104 004
m/a Corr.Step:[Y]
*EGB
3111
[Voff Display] Vsp-offset Display
3111 001
Regular
*EGB
Displays the Vsp-offset regular voltage.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
3111 002
Diffusion
*EGB
Displays the Vsp-offset diffusion voltage.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
3121
[Vsg Display] Vsg Display
3121 001
Regular
*EGB
Displays the Vsp regular voltage.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
3121 002
Diffusion
Displays the Vsp diffusion voltage.
[0.00 to 5.00 / 0.00 / 0.01 V/step]
5. Service Tables
232
5
Содержание G-P3
Страница 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Страница 11: ...10...
Страница 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Страница 91: ...3 Replacement and Adjustment 90 3...
Страница 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Страница 337: ...5 Service Tables 336 5...
Страница 411: ...MEMO 410...
Страница 412: ...MEMO 411...
Страница 413: ...MEMO 412...