Address
Function
Unit
Remarks
480438
International dial tone detection
time
20 ms
If 480438 contains FF, the
machine pauses for the
pause time (48043D /
48043E).
See Note 2 (Belgium).
480439
International dial tone reset time
(LOW)
48043A
International dial tone reset time
(HIGH)
48043B
International dial tone continuous
tone time
48043C
International dial tone permissible
drop time
48043D
International dial wait interval
(HIGH)
48043E
International dial wait interval
(LOW)
48043F
Country dial tone upper frequency
limit (HIGH)
Hz (BCD)
If both addresses contain
FF(F), tone detection is
disabled.
480440
Country dial tone upper frequency
limit (LOW)
480441
Country dial tone lower frequency
limit (HIGH)
If both addresses contain
FF(F), tone detection is
disabled.
480442
Country dial tone lower frequency
limit (LOW)
480443
Country dial tone detection time
20 ms
If 480443 contains FF, the
machine pauses for the
pause time (480448 /
480449).
480444
Country dial tone reset time (LOW)
480445
Country dial tone reset time
(HIGH)
480446
Country dial tone continuous tone
time
480447
Country dial tone permissible drop
time
480448
Country dial wait interval (LOW)
480449
Country dial wait interval (HIGH)
48044A
Time between opening or closing
the DO relay and opening the
OHDI relay
1 ms
See Notes 3 and 6.
Function 08 (parameter 11).
48044B
Break time for pulse dialling
1 ms
See Note 3. Function 08
(parameter 12).
48044C
Make time for pulse dialling
1 ms
See Note 3. Function 08
(parameter 13).
48044D
Time between final OHDI relay
closure and DO relay opening or
closing
1 ms
See Notes 6. Function 08
(parameter 14).
48044E
Minimum pause between dialled
digits (pulse dial mode)
20 ms
See Note 3. Function 08
(parameter 15).
48044F
Time waited when a pause is
entered at the operation panel
Function 08 (parameter 16).
480450
DTMF tone on time
1 ms
Function 08 (parameter 17).
480451
DTMF tone off time
Function 08 (parameter 18).
Ser
v
ice
T
abl
es
December 21st, 1995
SERVICE TABLES AND PROCEDURES
NCU PARAMETERS
4-59