Code
Meaning
Suggested Cause/Action
6-05
Facsimile data frame not received
within 18 s of CFR, but there was
no line fail (G3 ECM)
Check the line connection.
Check the connections from the FCE, FDU to the LIU.
Check for a bad line or defective remote terminal.
Replace the FCE or LIU.
Switch the rx cable equalizer on (bit switch 00, bit 1).
6-06
Coding/decoding error (G3 ECM)
Defective FCE.
Defective remote terminal.
6-08
PIP/PIN was received in reply to
PPS.NULL (G3 ECM)
The other end pressed Stop during communication.
The other terminal may be defective.
6-09
ERR received (G3 ECM)
Check for a noisy line.
Adjust the tx levels of the communicating machines.
See code 6-05.
6-10
Error frames still received at the
other end after all communication
attempts at 2400 bps (G3 ECM)
Check for line noise.
Adjust the tx level (use NCU parameter 01).
Check the line connection.
Defective remote terminal.
6-9