3-2-6. Speaker Test (Function 34)
1. Enter the service mode (see section 3-2-1).
2. Press Function, enter 34, then press SET.
3. The machine emits a tone from the speaker until OK or ERROR is pressed. Press the ‘‘>’’ key to switch be-
tween the two different volume levels.
If OK is pressed, the machine prints ‘‘VOL TEST OK’’ and goes to the Printer Test.
If ERROR is pressed, the machine prints ‘‘VOL TEST FAILED’’ and goes to the Printer Test.
3-2-7. Printer Test (Function 35)
1. Enter the service mode (see section 3-2-1).
2. Press Function, enter 35, then press PRINT.
3. A test pattern with diagonal lines is printed. After printing, the machine goes to standby mode.
3-2-8. PTT Test (Function 36)
1. Enter the service mode (see section 3-2-1).
2. Press Function, enter 36, then press SET.
3. Press ‘‘MDM’’ for modem test, ‘‘DTMF’’ for DTMF test, or ‘‘LEV.’’ for tx level adjustment.
4.1 Modem Test
The test starts from silence (the machine only goes off-hook), then by pressing the # key the signal changes to
9,600bps - 7,200bps - 4,800bps - 2,400bps - 300bps - 600Hz - 1100Hz - 2100Hz. (Press the * key to go back-
wards through the sequence.)
After you have finished the test, press EXIT to go back to step 3.
4.2 DTMF Test
Press a key on the dialpad (0 - 9, * and #) to test the DTMF signal.
After you have finished the test, press EXIT to go back to step 3.
Note that the machine will emit a DTMF signal with the country specific length, even if the slide switch on the
rear of the machine is not set at ‘‘Tone’’.
If you wish to get a continuous DTMF tone, set the slide switch at ‘‘Tone’’, switch off the power, then press the
required key on the dialpad.
4.3 Tx Level Adjustment
The current tx level setting is displayed in the upper right corner of the LCD. To change the setting, press # to
increment or press * to decrement. After adjustment, press EXIT to save the setting.
3-2-9. Frequency Test (Function 37)
1. Enter the service mode (see section 3-2-1).
2. Press Function, enter 37, then press SET.
3. The machine emits a sine wave of the displayed frequency. The frequency can be changed in units of 100Hz
by pressing # (increment) or * (decrement). Also, the output level can be changed by pressing LEV.
3-2-10. Burn-in Test (Function 38)
Do not use this function.
3-4