001 Low Coverage Coefficient: Bk
*ENG
[0 to 5 / 1 / 0.1 /step]
002 Low Coverage Coefficient: C
*ENG
003 Low Coverage Coefficient: M
*ENG
004 Low Coverage Coefficient: Y
*ENG
005 High Coverage Coefficient: Bk
*ENG
[0 to 5 / 1 / 0.01 V/step]
006 High Coverage Coefficient: C
*ENG
[0 to 5 / 0.5 / 0.01 V/step]
007 High Coverage Coefficient: M
*ENG
008 High Coverage Coefficient: Y
*ENG
009 Low Coverage: Threshold
*ENG
Adjusts the threshold of the low
coverage.
[0 to 20 / 3 / 0.1 %/step]
010 High Coverage: Threshold
*ENG
Adjusts the threshold of the high
coverage.
[0 to 100 / 60 / 1 %/step]
011 TC Upper Limit Correction
*ENG
[0 to 5 / 0 / 0.1 wt%/step]
012 Upper Limit TC: Display: Bk
*ENG
[1 to 15 / 10 / 0.1 wt% /step]
013 Upper Limit TC: Display: C
*ENG
014 Upper Limit TC: Display: M
*ENG
015 Upper Limit TC: Display: Y
*ENG
016 Process Control Execution Threshold
*ENG
[0 to 255 / 50 / 1 time/step]
3231
[Toner Supply: Setting]
Adjusts the coefficient of the toner supply time for each color. DFU
001 Replacement Coefficient:Bk
*ENG
[0.5 to 9.99 / 1.66 / 0.01 /step]
002 Replacement Coefficient: M
*ENG
[0.5 to 9.99 / 1.66/ 0.01 /step]
003 Replacement Coefficient: C
*ENG
[0.5 to 9.99 / 1.6 / 0.01 /step]
004 Replacement Coefficient: Y
*ENG
[0.5 to 9.99 / 1.66 / 0.01 /step]
Engine Service Mode
271
8
Содержание AP-P2 G188
Страница 1: ...Model AP P2 Machine Code G188 G189 Field Service Manual January 2009 Subject to change ...
Страница 2: ......
Страница 12: ...Electrical Component Defects 253 INDEX 255 10 ...
Страница 22: ...1 Product Information 20 1 ...
Страница 43: ...Item SP No Function Default Printer Installation 41 2 ...
Страница 100: ...3 Preventive Maintenance 98 3 ...
Страница 111: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 6 Exterior Covers 109 4 ...
Страница 115: ...3 Ozone filter A Ozone filter for IH inverter 1 IH inverter fan cover A hook Exterior Covers 113 4 ...
Страница 116: ...2 Filter B 3 Ozone filter C 4 Replacement and Adjustment 114 4 ...
Страница 128: ...6 Third duct fan cover A x 1 x 1 hook x 3 7 Third duct fan A hook x 1 4 Replacement and Adjustment 126 4 ...
Страница 164: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 4 Replacement and Adjustment 162 4 ...
Страница 169: ...3 Release five clamps and then turn the harness A aside 4 Paper feed clutch 1 bracket A x 2 x 1 x 1 Drive Unit 167 4 ...
Страница 174: ...6 Development clutch K A x 1 4 Replacement and Adjustment 172 4 ...
Страница 196: ...3 Pressure roller HP sensor bracket A x 1 x 1 4 Pressure roller HP sensor A hooks 4 Replacement and Adjustment 194 4 ...
Страница 199: ...9 Disconnect the connector A 10 Pull the Harness A in the arrow direction 11 Bracket A x 1 Fusing 197 4 ...
Страница 200: ...12 IH coil unit A First release the front side of the IH coil unit 4 Replacement and Adjustment 198 4 ...
Страница 243: ...Controller Self Diagnostics 241 5 ...
Страница 250: ...5 System Maintenance Reference 248 5 ...
Страница 251: ...6 Troubleshooting Service Call Conditions See the Appendices for the following information SC Tables 249 6 ...
Страница 256: ...6 Troubleshooting 254 6 ...
Страница 257: ...Model AP P2 Machine Code G188 G189 Appendices January 2009 Subject to change ...
Страница 258: ......
Страница 282: ...1 Appendix Specifications 24 1 ...
Страница 286: ...2 Appendix Preventive Maintenance Tables 28 2 ...
Страница 358: ...3 Appendix Service Call Conditions 100 3 ...
Страница 374: ...5 Appendix Troubleshooting Guide 116 5 ...
Страница 383: ...Sensor Locations Jam Detection 125 6 ...
Страница 384: ...6 Appendix Jam Detection 126 6 ...
Страница 392: ...7 Appendix Electrical Component Defects 134 7 ...