No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
548
A
Fusing unit rotation error
The heating roller rotation sensor does not detect change in the actuator for 0.5
seconds after the fusing/paper exit motor has turned on.
• Defective fusing/paper exit motor
• Deformed actuator for the heating roller rotation sensor
• Defective heating roller rotation sensor
• Broken connection between IH inverter and IOB
• Incorrectly set fusing unit
1. Check if the fusing unit is correctly set.
2. Check or replace the actuator for heating roller rotation sensor.
3. Replace the heating roller rotation sensor.
4. Replace the IH inverter.
5. Check the connection between IH inverter and IOB.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
551
A
Heating roller thermistor error
The temperature detected by the heating roller thermistor does not reach 0 °C for
7 seconds.
• Loose connection of heating roller thermistor
• Defective heating roller thermistor
1. Check that the heating roller thermistor is firmly connected.
2. Replace the heating roller thermistor.
3. Appendix: Service Call Conditions
58
3
Содержание AP-P2 G188
Страница 1: ...Model AP P2 Machine Code G188 G189 Field Service Manual January 2009 Subject to change ...
Страница 2: ......
Страница 12: ...Electrical Component Defects 253 INDEX 255 10 ...
Страница 22: ...1 Product Information 20 1 ...
Страница 43: ...Item SP No Function Default Printer Installation 41 2 ...
Страница 100: ...3 Preventive Maintenance 98 3 ...
Страница 111: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 6 Exterior Covers 109 4 ...
Страница 115: ...3 Ozone filter A Ozone filter for IH inverter 1 IH inverter fan cover A hook Exterior Covers 113 4 ...
Страница 116: ...2 Filter B 3 Ozone filter C 4 Replacement and Adjustment 114 4 ...
Страница 128: ...6 Third duct fan cover A x 1 x 1 hook x 3 7 Third duct fan A hook x 1 4 Replacement and Adjustment 126 4 ...
Страница 164: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 4 Replacement and Adjustment 162 4 ...
Страница 169: ...3 Release five clamps and then turn the harness A aside 4 Paper feed clutch 1 bracket A x 2 x 1 x 1 Drive Unit 167 4 ...
Страница 174: ...6 Development clutch K A x 1 4 Replacement and Adjustment 172 4 ...
Страница 196: ...3 Pressure roller HP sensor bracket A x 1 x 1 4 Pressure roller HP sensor A hooks 4 Replacement and Adjustment 194 4 ...
Страница 199: ...9 Disconnect the connector A 10 Pull the Harness A in the arrow direction 11 Bracket A x 1 Fusing 197 4 ...
Страница 200: ...12 IH coil unit A First release the front side of the IH coil unit 4 Replacement and Adjustment 198 4 ...
Страница 243: ...Controller Self Diagnostics 241 5 ...
Страница 250: ...5 System Maintenance Reference 248 5 ...
Страница 251: ...6 Troubleshooting Service Call Conditions See the Appendices for the following information SC Tables 249 6 ...
Страница 256: ...6 Troubleshooting 254 6 ...
Страница 257: ...Model AP P2 Machine Code G188 G189 Appendices January 2009 Subject to change ...
Страница 258: ......
Страница 282: ...1 Appendix Specifications 24 1 ...
Страница 286: ...2 Appendix Preventive Maintenance Tables 28 2 ...
Страница 358: ...3 Appendix Service Call Conditions 100 3 ...
Страница 374: ...5 Appendix Troubleshooting Guide 116 5 ...
Страница 383: ...Sensor Locations Jam Detection 125 6 ...
Страница 384: ...6 Appendix Jam Detection 126 6 ...
Страница 392: ...7 Appendix Electrical Component Defects 134 7 ...