Test pattern check
Possible cause/Countermeasure
The sub scan registrations of M, C, Y
are shifted.
• Defective image transfer belt
• Defective drive units
• Defective ID sensor
• Defective BCU
• Incorrect SP value
1. Replace the image transfer belt.
2. Replace the ID sensor.
3. Replace the drum motor.
4. Replace the BCU.
5. Adjust the value with SP2-182-022 to -039.
The skew of M, C, Y is different.
• Defective PCU
• Defective laser optics housing unit
• Defective IOB
1. Reinstall or replace the PCU.
2. Replace the laser optics housing unit.
3. Replace the IOB.
The sub scan lines are shifted. Shifted
lines appear cyclically.
• Defective PCU
• Defective drive unit
• Drum phase adjustment error
1. Do SP1-902-001 (Drum phase adjustment); see
Replacement and Adjustment – Drive Unit – Gear Unit for
details.
2. Reinstall or replace the PCU.
3. Check or replace the drive unit.
Troubleshooting Guide
115
5
Содержание AP-P2 G188
Страница 1: ...Model AP P2 Machine Code G188 G189 Field Service Manual January 2009 Subject to change ...
Страница 2: ......
Страница 12: ...Electrical Component Defects 253 INDEX 255 10 ...
Страница 22: ...1 Product Information 20 1 ...
Страница 43: ...Item SP No Function Default Printer Installation 41 2 ...
Страница 100: ...3 Preventive Maintenance 98 3 ...
Страница 111: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 6 Exterior Covers 109 4 ...
Страница 115: ...3 Ozone filter A Ozone filter for IH inverter 1 IH inverter fan cover A hook Exterior Covers 113 4 ...
Страница 116: ...2 Filter B 3 Ozone filter C 4 Replacement and Adjustment 114 4 ...
Страница 128: ...6 Third duct fan cover A x 1 x 1 hook x 3 7 Third duct fan A hook x 1 4 Replacement and Adjustment 126 4 ...
Страница 164: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 4 Replacement and Adjustment 162 4 ...
Страница 169: ...3 Release five clamps and then turn the harness A aside 4 Paper feed clutch 1 bracket A x 2 x 1 x 1 Drive Unit 167 4 ...
Страница 174: ...6 Development clutch K A x 1 4 Replacement and Adjustment 172 4 ...
Страница 196: ...3 Pressure roller HP sensor bracket A x 1 x 1 4 Pressure roller HP sensor A hooks 4 Replacement and Adjustment 194 4 ...
Страница 199: ...9 Disconnect the connector A 10 Pull the Harness A in the arrow direction 11 Bracket A x 1 Fusing 197 4 ...
Страница 200: ...12 IH coil unit A First release the front side of the IH coil unit 4 Replacement and Adjustment 198 4 ...
Страница 243: ...Controller Self Diagnostics 241 5 ...
Страница 250: ...5 System Maintenance Reference 248 5 ...
Страница 251: ...6 Troubleshooting Service Call Conditions See the Appendices for the following information SC Tables 249 6 ...
Страница 256: ...6 Troubleshooting 254 6 ...
Страница 257: ...Model AP P2 Machine Code G188 G189 Appendices January 2009 Subject to change ...
Страница 258: ......
Страница 282: ...1 Appendix Specifications 24 1 ...
Страница 286: ...2 Appendix Preventive Maintenance Tables 28 2 ...
Страница 358: ...3 Appendix Service Call Conditions 100 3 ...
Страница 374: ...5 Appendix Troubleshooting Guide 116 5 ...
Страница 383: ...Sensor Locations Jam Detection 125 6 ...
Страница 384: ...6 Appendix Jam Detection 126 6 ...
Страница 392: ...7 Appendix Electrical Component Defects 134 7 ...