• If the customer is using the optional Browser Unit, this unit must be installed again. For more, see
NVRAM Replacement Procedure
NVRAM on the BCU
1. Make sure that you have the SMC report (factory settings). This report comes with the machine.
2. Output the SMC data (
*
SP5-990-001) if possible.
3. Turn the main switch off.
4. Install an SD card into SD card slot 2. Then turn the main power on.
5. Copy the NVRAM data to an SD card (
*
SP5-824-001) if possible.
6. Turn off the main switch. Then unplug the power cord.
7. Replace the NVRAM on the BCU and reassemble the machine.
8. Plug in the power cord. Then turn the main switch on.
9. SC195 occurs.
10. Copy the data from the SD card to the NVRAM (
*
SP5-825-001) if you have successfully copied
them to the SD card.
11. Turn the main switch off. Then remove the SD card from SD card slot 2.
12. Turn the main switch on.
13. Specify the SP and UP mode settings.
14. Do the process control self-check.
NVRAM on the Controller
1. Make sure that you have the SMC report (factory settings). This report comes with the machine.
2. Output the SMC data (
*
SP5-990-001) if possible.
3. Turn the main switch off. Then unplug the power cord.
4. Install a New NVRAM on the controller. Then reassemble the machine.
5. Turn the main switch on.
6. SC995-02 occurs.
7. Turn the machine off and on.
8. Do the process control self-check.
9. Re-install the NetWare option if it has been installed.
Electrical Components
229
4
Содержание AP-P2 G188
Страница 1: ...Model AP P2 Machine Code G188 G189 Field Service Manual January 2009 Subject to change ...
Страница 2: ......
Страница 12: ...Electrical Component Defects 253 INDEX 255 10 ...
Страница 22: ...1 Product Information 20 1 ...
Страница 43: ...Item SP No Function Default Printer Installation 41 2 ...
Страница 100: ...3 Preventive Maintenance 98 3 ...
Страница 111: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 6 Exterior Covers 109 4 ...
Страница 115: ...3 Ozone filter A Ozone filter for IH inverter 1 IH inverter fan cover A hook Exterior Covers 113 4 ...
Страница 116: ...2 Filter B 3 Ozone filter C 4 Replacement and Adjustment 114 4 ...
Страница 128: ...6 Third duct fan cover A x 1 x 1 hook x 3 7 Third duct fan A hook x 1 4 Replacement and Adjustment 126 4 ...
Страница 164: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 4 Replacement and Adjustment 162 4 ...
Страница 169: ...3 Release five clamps and then turn the harness A aside 4 Paper feed clutch 1 bracket A x 2 x 1 x 1 Drive Unit 167 4 ...
Страница 174: ...6 Development clutch K A x 1 4 Replacement and Adjustment 172 4 ...
Страница 196: ...3 Pressure roller HP sensor bracket A x 1 x 1 4 Pressure roller HP sensor A hooks 4 Replacement and Adjustment 194 4 ...
Страница 199: ...9 Disconnect the connector A 10 Pull the Harness A in the arrow direction 11 Bracket A x 1 Fusing 197 4 ...
Страница 200: ...12 IH coil unit A First release the front side of the IH coil unit 4 Replacement and Adjustment 198 4 ...
Страница 243: ...Controller Self Diagnostics 241 5 ...
Страница 250: ...5 System Maintenance Reference 248 5 ...
Страница 251: ...6 Troubleshooting Service Call Conditions See the Appendices for the following information SC Tables 249 6 ...
Страница 256: ...6 Troubleshooting 254 6 ...
Страница 257: ...Model AP P2 Machine Code G188 G189 Appendices January 2009 Subject to change ...
Страница 258: ......
Страница 282: ...1 Appendix Specifications 24 1 ...
Страница 286: ...2 Appendix Preventive Maintenance Tables 28 2 ...
Страница 358: ...3 Appendix Service Call Conditions 100 3 ...
Страница 374: ...5 Appendix Troubleshooting Guide 116 5 ...
Страница 383: ...Sensor Locations Jam Detection 125 6 ...
Страница 384: ...6 Appendix Jam Detection 126 6 ...
Страница 392: ...7 Appendix Electrical Component Defects 134 7 ...