Safety notes for applications in potentially explosive areas
based on the Directive 2014/34/ EC (ATEX)
The valves are intended for use in a potentially
explosive area and are therefore subject to the
conformity assessment procedure of the directive
2014/34/EC (ATEX).
As part of this conformity assessment, an ignition
hazard analysis to EN 13463-1 to satisfy the funda-
mental safety and health requirements was conducted
with the following result:
♦
The valves do not have any ignition source of
their own.
♦
The valves are not covered by the scope of
application of the ATEX directive and therefore
do not need to be identified accordingly.
♦
The valves may be used in a potentially
explosive area.
It is imperative to observe the individual points of
intended use for application in a potentially explosive
area.
3.1 Intended use
Improper operation, even for brief periods, may
result in serious damage to the valve.
In connection with explosion protection, potential
sources of ignition (overheating, electrostatic and
induced charges, mechanical and electric sparks)
may result from these improper operation; their
occurrence can only be prevented by adhering to
the intended use.
Furthermore, reference is made in this connection to
the Directive 95/C332/06 (ATEX 118a) which contains
the minimum regulations for improving the occupa-
tional health and safety of the workers who may be at
risk from an explosive atmosphere.
A difference is made between two cases for the use of
chargeable liquids (conductivity < 10
-8
S/m):
1. Chargeable liquid and non-conductive lining
Charges can occur on the lining surface. As a
result, this can produce discharges inside and
outside the valve.
a) Discharges inside the valve
However, these discharges inside the valve cannot
cause ignitions if the valve is completely filled with
medium.
If the valve is not completely filled with medium,
e.g. during evacuation and filling, the formation of
an explosive atmosphere must be prevented, e.g.
by superimposing a layer of nitrogen. It is recom-
mended to wait 1 hour before removing the valve
from the plant in order to permit the elimination of
static peak charges.
This means that, to safely prevent ignitions, the
valve must be completely filled with medium at all
times or else a potentially explosive atmosphere
must be excluded by superimposing a layer of inert
gas.
b) Discharges outside the valve
At the points where the non-conductive lining e.g.
protrudes on the sealing surfaces to the outside or
gets contact with the atmosphere on the outside, it
may lead to discharges from the lining to nearby
valves or attachments.
To safely avoid explosion hazards and accidents,
therefore, the atmosphere surrounding the valve
must not be explosive.
2. Chargeable liquid and conductive lining
No hazardous charges can occur as charges are
discharged direct via the lining and shell (surface
resistance <10
9
Ohm, leakage resistance <10
6
Ohm).
If non-conductive versions of individual compo-
nents are installed in the valve, it may restrict the
permitted ATEX zone and explosion subgroup
when operating the valve despite the conductive
lining of the armor plating (see “Technical rules for
hazardous substances: Avoidance of ignition haz-
ards due to electrostatic charges” (TRGS 727)).
In these cases, consult the manufacturer.
Static discharges of non-conductive linings are
only produced through the interaction with a
non-conductive medium and are therefore the
responsibility of the plant operator.
Static discharges are not sources of ignition
which stem from the valves themselves!
♦
The temperature of the medium must not exceed
the temperature of the corresponding temperature
class or the maximum admissible medium temper-
ature as per the operating manual.
♦
If the valve is heated (e.g. heating jacket), it must
be ensured that the temperature classes pre-
scribed in the Annex are observed.
♦
To achieve safe and reliable operation, it must be
ensured in inspections at regular intervals that the
valve is properly serviced and kept in technically
perfect order.
♦
Increased wear to the valve can be expected with
the conveyance of liquids containing abrasive
constituents. The inspection intervals are to be
reduced compared with the usual times.
♦
Actuators and electric peripherals, such as
temperature, pressure and flow sensors etc., must
comply with the valid safety requirements and
explosion protection provisions.
♦
The valve must be grounded.
♦
This can be achieved in the simplest way via the
pipe screws using tooth lock washers.
♦
Otherwise grounding must be ensured by different
measures e.g. a cable link.
♦
Plastic-lined valves must not be operated with
carbon disulphide.