Calibration
The Tracer AV can be calibrated using the
Zero
and
Units
keys or EDP commands. Both methods consist of the following
steps:
• Zero calibration
• Entering the test weight value
• Span calibration
• Optional rezero calibration for test weights using hooks or other additional items.
Figure 4-1. Calibration (CALIBR) Menu
The default calibration feature can also be used, which utilizes a more user-friendly procedure; however, not all options are
available in default calibration.
Figure 4-2. Default Calibration (DEFCAL) Menu
4.1 Default Calibration
If using a 500 lb or 300 lb scale, you can select it from the
DEFCAL
menu. This automatically uses the settings shown in
Primary
500 lb x 1 lb
Secondary
250 kg x .5 kg
SP1 Trip
50 lb
SP2
Off
Digital Filter
8,8,8
Zero Tracking
3D
Table 4-1. 500 Lb Scale Settings
Primary
300 lb x 1 lb
Secondary
150 kg x .5 kg
SP1 Trip
50 lb
SP2
Off
Digital Filter
8,8,8
Zero Tracking
3D
Table 4-2. 300 Lb Scale Settings