Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
13
Figure 3-1. Setup Mode Menu Navigation
3.1.3 Setting Numeric Values For Parameters
1. Press
Zero
to immediately accept the current value and navigate to the next menu item.
2. Press
Units
to enter edit mode
.
The leftmost digit will flash to indicate it can be altered.
3. Press
Zero
to increment to the desired value.
4. When the value is correct, press
Units
to move to the next digit.
3.1.4 Editing Integers
1. By pressing
Units
, navigate all the way to the right (beyond all ‘-’
characters until there are no segments flashing).
Figure 3-2. Editing Procedure for Numeric Values
The ‘-’ characters are placeholders for appending or removing digits at the end of numbers that exceed the six-digit
display.
2. Press
Zero
to accept the modified value.
3.1.5 Editing Floating Point (Decimal Point Position)
1. By pressing
Units
, navigate all the way to the right (beyond all ‘-’
characters until there are no segments flashing).
2. Press
Zero
to initialize editing of decimal point position.
3. Press
Units
to move the decimal point to the desired position.
The decimal point will move forward one position with the
Units
button and wrap around until the
Zero
button is
pressed to select the position.
4. When the decimal point is in the desired position, press
Zero
.
1
st
Level
Parameter
Default value
Value
1
st
Level
Parameter
2
nd
Level
Parameter
2
nd
Level
Parameter
Value
Value
When moving through values below the first menu, press UNITS to view the
selections. Press ZERO to set the parameter and move to the next parameter on the
leval above.
Increment Value/
Save Value Entered and
return to level above
Change Digit Selection
Note