4.4.7 Setup – Stream Format Menu
Figure 4-16. Setup – Stream Format Menu
Parameter
Description
sfmt
Stream Format – Specifies the stream format used for streaming output of scale data or specifies the expected input for a
serial scale;
Settings:
RLWS
(default) –
Rice Lake Weighing Systems stream format (
)
CRDNAL – Cardinal stream format (
)
WTRNIX
– Avery Weigh-Tronix stream format (
)
TOLEDO – Mettler Toledo stream format (
)
CUSTOM – Custom stream format
custom
Custom Stream Format – Specifies the custom stream format; only displays if SFMT is set to CUSTOM;
Enter characters: Alphanumeric entry up to 1000 characters
gross
Gross – Mode token when streaming the gross weight;
Enter characters: Alphanumeric entry up to 8 characters,
G
(default)
tare
Tare – Mode token when streaming the tare weight;
Enter characters: Alphanumeric entry up to 8 characters,
T
(default)
net
Net – Mode token when streaming the net weight;
Enter characters: Alphanumeric entry up to 8 characters,
N
(default)
pos
Positive – Polarity token when the weight is positive;
Settings:
SPACE
(default), NONE, +
neg
Negative – Polarity token when the weight is negative;
Settings: SPACE, NONE,
–
(default)
pri
Primary – Units token when streaming primary units;
Enter characters: Alphanumeric entry up to 8 characters,
L
(default)
sec
Secondary – Units token when streaming secondary units;
Enter characters: Alphanumeric entry up to 8 characters,
K
(default)
zero
Zero – Status token when the weight is at center of zero;
Enter characters: Alphanumeric entry up to 2 characters,
Z
(default)
motion
Motion – Status token when the weight is in motion;
Enter characters: Alphanumeric entry up to 2 characters,
M
(default)
range
Range – Status token when the weight is out of range;
Enter characters: Alphanumeric entry up to 2 characters,
O
(default)
ok
OK – Status token when the weight is OK (not invalid, out of range, at zero or in motion);
Enter characters: Alphanumeric entry
up to 2 characters (default is a space)
invlid
Invalid – Status token when streaming an invalid weight;
Enter characters: Alphanumeric entry up to 2 characters,
I
(default)
Table 4-15. Setup – Stream Format Menu Parameters
Setup
sformt
sfmt
custom
Displays if
sfmt
is set to
custom
gross
tare
net
neg
pri
pos
sec
zero
range
ok