![Rice Lake Synergy 680HE Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/rice-lake/synergy-680he/synergy-680he_technical-manual_1453958038.webp)
680HE Synergy Indicator
32
Visit our website
4.4.5.2 Industrial Settings Menu
The industrial settings menu (
indset
) only displays if the regulation parameter (
regula
) is set to industrial (
indust
).
Figure 4-14. Industrial Settings Menu
Parameter
Description
agency
Audit Agency – Audit trail display agency format;
Settings:
NTEP
(default), CANADA, NONE, OIML
snpsht
Snap Shot – Display or scale weight source;
Settings:
DISPLAY
(default), SCALE
htare
Hold Tare – Allow tare in display hold;
Settings:
NO
(default), YES
ztare
Zero Tare – Remove tare on zero;
Settings:
NO
(default), YES
ktare
Keyed Tare – Always allow keyed tare;
Settings:
YES
(default), NO
mtare
Multiple Tare – Replaces existing tare when the tare key is pressed;
Setti
ngs:
REPLAC
(default), REMOVE, NOTHNG
ntare
Negative/Zero Tare – Allow negative or zero tare;
Settings:
NO
(default), YES
ctare
Clear Tare/Accumulator – Allow clear key to clear tare/accumulator;
Settings:
YES
(default), NO
negtot
Negative Total – Allow total scale to display negative value;
Settings:
NO
(default), YES
Prtmot
Print In Motion – Allow print while in motion;
Settings:
NO
(default), YES
prntpt
Print Preset Tare – Add preset tare (PT) to keyed tare print;
Settings:
YES
(default), NO
prthld
Print Hold – Print during display hold;
Settings:
NO
(default), YES
hldwgh
Hold Weighment – Allow weighment during display hold;
Settings:
NO
(default), YES
motwgh
Motion Weighment – Allow weighment in motion;
Settings:
NO
(default), YES
ovrbse
Overload Base – Zero base for overload calculation;
Setting
s:
CALIB
(default), SCALE
rtare
Round Button Tare – Round pushbutton tare to the nearest display division;
Settings:
NO
(default), YES
rktare
Round Keyed Tare – Round keyed tare to the nearest display division;
Settings:
NO
(default), YES
aztnet
AZT On Net Value – Perform auto zero tracking on net value;
Settings:
NO
(default), YES
mctare
Manual Clear Tare – Allow manual clearing of the tare value;
Settings:
YES
(default), NO
tarmot
Tare In Motion – Allow tare in motion;
Settings:
NO
(default), YES
zromot
Zero In Motion – Allow scale to be zeroed while in motion;
Settings:
NO
(default), YES
uldwgh
Underload Weight – Underload weight value in display divisions;
Enter value: 1–999999,
20
(default)
Table 4-13. Industrial Settings Menu Parameters
Setup
Progrm
indset
AGencY
SNPSHT
HTARE
NEGTOT
PRTMOT
PRnTPT
RKTARE
AZTNET
MCTARE
ZTARE
KTARE
PRTHLD
HLDWGH
TARMOT
ZRoMOT
MTARE
MOTWGH
NTARE
CTARE
OVRBSe
RTARE
ULDWGH
Содержание Synergy 680HE