5. Thread the exposed 90° fitting to the load cell, making sure the cable does not twist.
6. Insert cable through second half of fitting and conduit, then re-install cover plate to 90°
fitting.
• This method prevents connections from being twisted off inside the load cell
Figure 4-3. Installing 90
°
Fitting to Load Cell
7. Place the load cell link over the end of the cell and install the assembly onto the top of the baseplate.
8. Apply anti-seize compound to threads of load cell bolts before installing. Torque load cell bolts 50 – 75 ft-lb.
Figure 4-4. Load cell Access
9. Position flex cable so that a loop can be made in it and the end can be attached to the rigid conduit.