Ishida OMNi-4000 Error Codes and Troubleshooting
15.5 ERROR CODE (0600 - )
No.
Message
Symptom or Phenomenon
Check
0633 "THE PROBLEM AROSE IN THE
APPLICATOR"
There is no Applicator program (firmware)
[Sub-error]
-0000 Bad checksum or no application.
-0001 The application ran too quickly.
1. Download the firmware file to the P-916 Applicator Controller board.
a. Test Menu, Program Download.
b. Select firmware (B0509A) - yellow highlight.
c. Execute.
2. If the same error recurs, replace P-916.
After replacing the P-916 board perform the following steps:
a. Download firmware to P-916. See step 1 above.
b. Initialize the Applicator [Test Menu, Applicator Adjustment,
page 2].
c. After initialization, confirm the prompt to send backup
settings from main memory.
d. If no backup is available, manually program settings in
Test Menu, Applicator Adjustment, page 1.
0650 THERE WAS NO RESPONSE FROM
THE APPLICATOR
Unable to communicate between the console and
applicator.
[OK]
-> Cut communication with the applicator. Operate
without the applicator.
[RETRY]
-> Check connection with the applicator. The error
is cleared if connection can be confirmed.
[Remarks] It is possible to operate without the
applicator after pressing the [OK] button.
Press the [RETRY] key and attempt communication. The consider the
following causes if the error does not clear:
1
)
Unplugged connector: P-916: XJ17, XJ27 (0650-0017)
2
)
Shorted harness
3
)
Board P-910 malfunction
4
)
Board P-918 malfunction
5
)
Board P-916 malfunction
Rev. Feb 2015
28/
40
Yellow highlights indicate updates