![Rice Lake IQ plus 210 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/rice-lake/iq-plus-210/iq-plus-210_installation-manual_1453897034.webp)
IQ plus 210 Installation Manual
28
Visit our website
6.6 Specifications
IQ plus 210 Indicator
Power
Line Voltages
115 or 230 VAC
Frequency
50 or 60 Hz
Power Consumption
70 mA @ 115 VAC (8W)
35 mA @ 230 VAC (8W)
Fusing
115 VAC
2 x 200 mA TR5 subminiature fuses
Wickmann Time-Lag 19374 Series
UL Listed, CSA Certified
230
VAC 2 x 100 mA TR5 subminiature fuses
Wickmann Time-Lag 19372 Series UL
Recognized, VDE Approved
Analog Specifications
Full Scale Input Signal
Up to 35 mV
Excitation Voltage
10 ± 0.25 VDC,
4 x 350Ω load cells
Analog Signal
Input Range
0.6 mV/V – 4.5 mV/V
Analog Signal
Sensitivity
0.3 µV/graduation minimum,
1.5 µV/grad recommended
Input Impedance
200 MΩ, typical
Display Resolution
10 000 dd
Input Sensitivity
155 nV per internal count
System Linearity
Within 0.01% of full scale
Calibration Method
Software, constants stored in
EEPROM
Common Mode
Voltage
–1.05 to +0.95 V, referred to earth
RFI Protection
Signal, excitation, and sense lines
protected by capacitor bypass
Digital Specifications
Digital Inputs
2 inputs, TTL or switch closure,
active-low
Digital Filter
Software selectable
Serial Communications
Serial Port
Full duplex RS-232; 9600, 4800,
2400, 1200 bps; 7 or 8 data bits;
even, odd, or no parity
Operator Interface
Display
6-digit LED display. 7-segment, .8 in
(20 mm) digits
LED annunciators
Negative value, center of zero, motion,
kg, g, lb, oz
Keypad
2 piezo switches
Environmental
Operating Temperature
–10 to +40°C (legal);
–10 to +50°C (industrial)
Storage Temperature
–25 to +70°C
Humidity
0–95% relative humidity
Altitude
2000 m (6500 ft) maximum
Enclosure
Enclosure Dimensions
9.5 in x 6 in x 2.75 in
24 cm x 15 cm x 7 cm
Weight
6.1 lb (2.8 Kg)
Rating/Material
NEMA 4X indoor use only, stainless steel
Approvals
NTEP
CoC Number
00-045
Accuracy Class
III/III L
UL
File Number
E151461
Measurement Canada Approved
Approval
AM-5374
Accuracy Class
III/III HD
The IQ210 complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
• This device may not cause harmful interference.
• This device must accept any interference received,
including interference that may cause undesired
operation.
UL
C
US
LISTED
®